Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 229
Message text: QCI: test temperature and test pressure values and units are replaced
The system will neglect the parameters entered as test conditions for
the test density and test heating value, and use the parameters
maintained with the unit of measure for the test density or test
heating value instead. This replacement of test conditions will only be
carried out if the unit of measure entered as a test density or test
heating value unit is itself maintained in customizing ( Maintain units
of measure ) with additional descriptive parameters. This replacement
is controlled by the settings of the conversion group.
The system continues processing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3229
- QCI: test temperature and test pressure values and units are replaced ?The SAP error message O3229, which indicates "QCI: test temperature and test pressure values and units are replaced," typically arises in the context of Quality Management (QM) within SAP. This error is related to the Quality Inspection (QI) process, particularly when dealing with inspection characteristics that involve temperature and pressure measurements.
Cause:
Unit of Measure Mismatch: The error often occurs when the units of measure for temperature and pressure in the inspection lot do not match the expected units defined in the inspection characteristics. For example, if the system expects temperature in Celsius but receives it in Fahrenheit, or if pressure is expected in bar but is provided in psi.
Configuration Issues: There may be issues in the configuration of the inspection characteristics or the material master data, where the expected units are not properly set up.
Data Entry Errors: Incorrect data entry during the inspection process can lead to this error, especially if the values entered do not conform to the expected formats or units.
Solution:
Check Inspection Characteristics: Review the inspection characteristics defined for the material in the Quality Management module. Ensure that the units of measure for temperature and pressure are correctly configured.
Verify Material Master Data: Check the material master data to ensure that the correct units of measure are assigned for the relevant characteristics. This can be done in the material master under the Quality Management view.
Correct Data Entry: If the error is due to incorrect data entry, ensure that the values entered during the inspection process are in the correct format and units. Train users on the correct data entry procedures if necessary.
Adjust Configuration: If the issue is related to configuration, you may need to adjust the settings in the Quality Management module. This may involve working with your SAP configuration team to ensure that the settings align with your business processes.
Testing and Validation: After making changes, conduct tests to validate that the error no longer occurs and that the inspection process functions as expected.
Related Information:
If the problem persists after following these steps, it may be beneficial to consult with SAP support or a qualified SAP consultant for further assistance.
Get instant SAP help. Start your 7-day free trial now.
O3228
QCI: For conversion goup &, use FMTYP & instead of &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3227
QCI: SGERG-88, conflicting result for N2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3230
& inactive default sets will be saved and must be activated before use
What causes this issue? You have maintained several default sets and saved the data. However, not all default sets have been activated . This is indi...
O3231
QCI: Base temperature and base pressure values and units are replaced
What causes this issue? In the conversion group, an indicator is set to activate additional conversion routines. The routines convert the base densit...
Click on this link to search all SAP messages.