Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 106
Message text: SI unit for dimension "heating value" not found in Table T006
There is no SI unit for the "heating value" dimension defined in Table
T006.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The Quantity Conversion Interface (QCI) stops processing.
Declare the SI unit for that dimension in Table T006 (Transaction CUNI).
Use the entries delivered with IS OIL template client 065 as a blueprint
for this activity.
Error message extract from SAP system. Copyright SAP SE.
O3106
- SI unit for dimension "heating value" not found in Table T006 ?The SAP error message O3106 indicates that the system is unable to find the appropriate SI unit for the dimension "heating value" in the unit of measure table (T006). This typically occurs when you are trying to work with materials or products that require a specific unit of measure that has not been defined in the system.
Cause: Missing Unit of Measure: The specific SI unit for "heating value" (e.g., MJ/kg, kJ/kg) is not defined in the T006 table. Incorrect Configuration: The configuration for the material or product may not be set up correctly, leading to the system not recognizing the required unit. Data Entry Error: There may be a typo or incorrect entry in the material master or related configuration.
Solution: Check T006 Table: Go to transaction code SE16N or SE11 and enter the table name T006. Check if the required unit of measure for "heating value" is present. If it is not, you will need to
Get instant SAP help. Sign up for our Free Essentials Plan.
O3104
Table OIB08 contains entries from user &; no update possible
What causes this issue? Report ROIBSCAN_CHECK has been used by another user, who created entries in Table OIB08.System Response The system issues an...
O3103
Material has to be passed for the quantity conversion
What causes this issue? The quantity conversion is requested to be based on static conversion factors that are maintained in the material master. Thu...
O3107
The Oil BOM cost indicator can only be set for Oil BOMs
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3108
Oil BOM item cat. has to have same settings for hdr and comp. item cat.
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...