Do you have any question about this error?
Message type: E = Error
Message class: KJCCSJ3_BI01 - Japanese Estimation Procedure
Message number: 030
Message text: Device &1, Register &2, MR &3: No previous actual meter reading exists
Device &V1&, register &V2&, is planned for reestimation.
Meter reading &V3& is an estimated meter reading and must be
reestimated.
INCLUDE ISU_JAP_MESSAGE OBJECT DOKU ID TX
In this case a preceding actual meter reading is missing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the meter readings for the aformentioned register, and correct the
meter readings so that a reestimation is possible.
Error message extract from SAP system. Copyright SAP SE.
KJCCSJ3_BI01030
- Device &1, Register &2, MR &3: No previous actual meter reading exists ?The SAP error message KJCCSJ3_BI01030 indicates that there is no previous actual meter reading available for the specified device, register, and measurement point. This error typically occurs in the context of billing or meter reading processes within SAP IS-U (Industry Solution for Utilities).
Cause:
- No Previous Reading: The most common cause is that the system is trying to process a new meter reading, but there is no prior actual reading recorded for the specified device and register.
- Data Entry Error: There may have been an error in data entry, where the previous reading was not recorded or was incorrectly deleted.
- Configuration Issues: There could be issues with the configuration of the meter reading or billing processes in SAP.
- Timing Issues: If the system is trying to process readings in a sequence that does not align with the actual readings recorded, this error may occur.
Solution:
- Check Previous Readings: Verify if there are any actual meter readings recorded for the specified device and register. You can do this by checking the relevant tables in SAP (e.g., EAM or IS-U tables).
- Enter Missing Readings: If there are no previous readings, you may need to enter a previous actual meter reading manually, if applicable.
- Review Data Entry: Ensure that all meter readings are entered correctly and that there are no missing entries in the system.
- Configuration Review: Check the configuration settings for meter reading and billing processes to ensure they are set up correctly.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling meter readings and billing processes.
- Contact Support: If the issue persists, consider reaching out to your SAP support team or consulting with SAP experts for further assistance.
Related Information:
EL30
(Display Meter Reading) or EL31
(Create Meter Reading) to manage meter readings.EABR
(Meter Reading Document) and EAMR
(Meter Reading Results), to analyze the data.By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
KJCCSJ3_BI01029
Reserved
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
KJCCSJ3_BI01028
Reserved
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
KJCCSJ3_BI01031
Device &1, Register &2: Leading installation is not uniquely determined
What causes this issue? Device &V1&, register &V2&, is installed in at least two installations ( &V3& and &V4&). At l...
KJCCSJ3_BI01032
Equipment No. &1, Register &2, Date &3 not found in internal table &4
What causes this issue? INTERNAL ERRORSystem Response The system issues an error message and will not allow you to continue with this transaction un...
Click on this link to search all SAP messages.