Do you have any question about this error?
Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 150
Message text: Measuring point &2 cannot be forwarded to meas. point &1 (recursiveness)
You wanted to define a transfer of
<DS:GLOS.measurement_reading>measurement</> or
<DS:GLOS.counter_reading>counter readings</> from
<DS:GLOS.measuring_point>measuring point</> &V2& to measuring point
&V1&.
An automatic system check has recognized that this measurement reading
transfer would be recursive.
This is not allowed by the system.
Check your entries.
Error message extract from SAP system. Copyright SAP SE.
IR150
- Measuring point &2 cannot be forwarded to meas. point &1 (recursiveness) ?The SAP error message IR150 indicates that there is a problem with the measurement point configuration in the SAP system, specifically related to the recursiveness of measurement points. This error typically occurs when there is an attempt to forward a measurement point to itself or to another measurement point that eventually leads back to the original measurement point, creating a circular reference.
Cause:
- Circular Reference: The most common cause of this error is that the measurement point you are trying to forward is already linked to another measurement point that eventually points back to it, creating a loop.
- Incorrect Configuration: There may be incorrect or incomplete configuration in the measurement point hierarchy or in the relationships between measurement points.
- Data Integrity Issues: There could be issues with the data integrity in the measurement point master data, such as incorrect entries or missing relationships.
Solution:
Check Measurement Point Relationships:
- Review the relationships between the measurement points involved. Ensure that there are no circular references.
- Use transaction codes like
IK01
(Create Measuring Point) orIK02
(Change Measuring Point) to check the configuration of the measurement points.Correct Configuration:
- If you find a circular reference, you will need to adjust the configuration to eliminate the loop. This may involve changing the forwarding settings or reassigning measurement points.
- Ensure that each measurement point is only forwarded to valid and appropriate measurement points.
Data Validation:
- Validate the measurement point data to ensure that all entries are correct and that there are no inconsistencies.
- You can use transaction
IK03
(Display Measuring Point) to view the details of the measurement points.Consult Documentation:
- Refer to SAP documentation or help resources for guidance on configuring measurement points and understanding the relationships between them.
Testing:
- After making changes, test the configuration to ensure that the error does not reoccur and that the measurement points are functioning as expected.
Related Information:
IK01
, IK02
, IK03
, and IK04
for managing measurement points.By following these steps, you should be able to identify the cause of the IR150 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
IR149
Measurement reading transfer stopped for &1 measuring points
What causes this issue? It is a requirement for the transfer of <DS:GLOS.measurement_reading>measurement</> or <DS:GLOS.counter_readin...
IR148
Measuring point &2 locked by user &1 -> Structure changes not possible
What causes this issue? You are trying to change the structure of a hierarchy of technical objects, for example, by dismantling a piece of equipment ...
IR151
Transfer measurement readings to a measuring point of the same object?
What causes this issue? <DS:GLOS.measuring_point>Measuring point</> &V1&, from which a measurement reading is to be transferred (...
IR152
MeasPoint has different characacter -> MeasReading transfer not possible
What causes this issue? The <DS:GLOS.measuring_point>measuring point</> &V3& from which the measurement readings are to be transf...
Click on this link to search all SAP messages.