Do you have any question about this error?
Message type: E = Error
Message class: HRBAS00CUST - HR: Customizing Checks
Message number: 107
Message text: The single screen for infotype &1 is dynpro &2 not 2000
The single screen for infotype &V1& is not the standard screen 2000,
but screen &V2&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check whether the screen number &V2& is correct. If in doubt, you
should reset the entry to 2000.
The check is based on the field EDYNR in table T777D.
Error message extract from SAP system. Copyright SAP SE.
HRBAS00CUST107
- The single screen for infotype &1 is dynpro &2 not 2000 ?The SAP error message HRBAS00CUST107 indicates that there is a configuration issue related to the infotype screen in the Human Resources (HR) module. Specifically, the error states that the single screen for the specified infotype (
&1
) is not using the expected screen number (2000
), which is typically the standard screen for infotypes in SAP.Cause:
- Custom Infotype Configuration: The infotype may have been customized or incorrectly configured, leading to the assignment of a different screen number instead of the standard
2000
.- Screen Modification: If the screen for the infotype has been modified or replaced with a custom screen that does not adhere to the expected configuration, this error can occur.
- Missing or Incorrect Screen Assignment: The infotype may not be correctly assigned to the appropriate screen in the configuration settings.
Solution:
Check Infotype Configuration:
- Go to transaction code SE11 (Data Dictionary) and check the infotype definition.
- Ensure that the infotype is correctly configured to use screen
2000
or the appropriate screen as per your requirements.Review Screen Assignment:
- Use transaction code SE80 (Object Navigator) to navigate to the infotype and check the screen assignment.
- Verify that the screen number assigned to the infotype is correct and matches the expected configuration.
Adjust Customizations:
- If there are custom screens or modifications, review the custom code to ensure it aligns with the standard SAP practices.
- If necessary, revert to the standard screen or adjust the custom screen to meet the requirements.
Transport Requests:
- If changes were made in a development environment, ensure that the transport requests are correctly moved to the quality or production environment.
Consult Documentation:
- Review SAP documentation or notes related to the specific infotype for any known issues or additional configuration steps.
Related Information:
2000
, which is used for single-screen data entry.If the issue persists after following these steps, it may be beneficial to consult with an SAP HR functional consultant or reach out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
HRBAS00CUST106
Infotype &1 has no P&1 structure
What causes this issue? The definition of infotype &V1& does not contain a work structure, the so-called P&V1& structure. The structu...
HRBAS00CUST105
Infotype &1 is in the wrong number range
What causes this issue? Infotype &V1& is a Personnel Planning infotype. As such, it should not have a number less than 1000, since the number...
HRBAS00CUST108
The list screen for infotype &1 is dynpro &2 not 3000
What causes this issue? The screen for the list screen differs from the standard number "3000".System Response The system issues an error ...
HRBAS00CUST109
The dialog dynpro for infotype &1 is &2 not 1000
What causes this issue? The dialog module entered in the settings for infotype &V1& refers to screen &V2&. This is not the standard s...
Click on this link to search all SAP messages.