Do you have any question about this error?
Message type: E = Error
Message class: HRBAS00CUST - HR: Customizing Checks
Message number: 109
Message text: The dialog dynpro for infotype &1 is &2 not 1000
The dialog module entered in the settings for infotype &V1& refers to
screen &V2&. This is not the standard screen 1000 for the start of a
dialog on an infotype data screen.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Change the dialog module in such a way that it calls the standard
dialog screen 1000 of the infotype module pool.
The system checks the dialog module in T777D-DIALG. It is not defined
in TDCT.
Error message extract from SAP system. Copyright SAP SE.
HRBAS00CUST109
- The dialog dynpro for infotype &1 is &2 not 1000 ?The SAP error message HRBAS00CUST109 indicates that there is an issue with the dialog screen (dynpro) configuration for a specific infotype in the Human Resources (HR) module. The message states that the dialog dynpro for the specified infotype (&1) is not set to the expected value (1000). This typically means that the system is expecting a specific screen number for the infotype, but it has been configured incorrectly.
Cause:
- Incorrect Screen Number: The infotype is configured to use a screen number that is not 1000, which is the standard screen for most infotypes.
- Custom Development: If there has been custom development or modifications made to the infotype, it may have been assigned a different screen number.
- Configuration Issues: There may be issues in the configuration settings for the infotype in the SAP system.
Solution:
Check Infotype Configuration:
- Go to transaction SE11 (Data Dictionary) and check the infotype definition.
- Verify the screen number assigned to the infotype. It should typically be 1000 for standard infotypes.
Adjust Screen Number:
- If the screen number is incorrect, you may need to adjust it back to 1000 or to the appropriate screen number that is intended for use.
- This can be done in transaction PM01 (for customizing infotypes) or through the relevant configuration transaction for HR infotypes.
Review Custom Code:
- If there is custom code or enhancements related to the infotype, review that code to ensure it is not inadvertently changing the screen number or causing the issue.
Transport Requests:
- If changes were made in a development environment, ensure that the transport requests are correctly moved to the quality and production environments.
Testing:
- After making the necessary changes, test the infotype to ensure that the error no longer occurs and that the infotype functions as expected.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with an SAP HR functional consultant or a technical consultant who can provide deeper insights into the specific configuration and customizations in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
HRBAS00CUST108
The list screen for infotype &1 is dynpro &2 not 3000
What causes this issue? The screen for the list screen differs from the standard number "3000".System Response The system issues an error ...
HRBAS00CUST107
The single screen for infotype &1 is dynpro &2 not 2000
What causes this issue? The single screen for infotype &V1& is not the standard screen 2000, but screen &V2&.System Response The sys...
HRBAS00CUST110
Program &2 for infotype &1 does not exist
What causes this issue? For infotype &V1& the system checks the existence of the program &V2&. However, the program does not exist. T...
HRBAS00CUST111
The dialog module &2 for infotype &1 does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.