Do you have any question about this error?
Message type: E = Error
Message class: GG - Messages for FI-SL customizing
Message number: 699
Message text: Blocking object & is incorrect
Blocking object <(>&<)> that you entered is incorrect. The following
conditions must be fulfilled:
a) The blocking object must be defined in the Data Dictionary.
b) The blocking object has a maximum length of 10 characters, and is
named EZxxxxxxxE (xxxxxxx is max. 7 characters long and can be defined
by the user) or EGxxxxxxx (for SAP standard tables). It is common to
use the name of the table to be installed for xxxxxxx.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Note the above conditions. You can use object EGGLT0E from table GLT0
as a reference for a blocking object.
Error message extract from SAP system. Copyright SAP SE.
GG699
- Blocking object & is incorrect ?The SAP error message GG699, which states "Blocking object & is incorrect," typically occurs in the context of SAP's General Ledger (G/L) accounting or during the execution of certain transactions that involve blocking objects. This error indicates that there is an issue with the blocking object specified in the transaction or process you are trying to execute.
Cause:
- Incorrect Blocking Object: The blocking object specified in the transaction does not exist or is not valid in the current context.
- Configuration Issues: There may be configuration issues in the system that lead to the blocking object being incorrectly defined or referenced.
- Data Inconsistencies: There could be inconsistencies in the data that are causing the system to not recognize the blocking object.
- Authorization Issues: The user may not have the necessary authorizations to access or modify the blocking object.
Solution:
- Verify the Blocking Object: Check the blocking object specified in the transaction. Ensure that it is correctly defined and exists in the system.
- Check Configuration: Review the configuration settings related to the blocking object. Ensure that all necessary settings are correctly configured.
- Data Consistency Check: Run data consistency checks to identify any inconsistencies that may be causing the issue. This may involve checking related tables or data entries.
- User Authorizations: Ensure that the user executing the transaction has the necessary authorizations to access and modify the blocking object.
- Consult Documentation: Refer to SAP documentation or notes related to the specific transaction or process you are working with for additional guidance.
- Contact SAP Support: If the issue persists, consider reaching out to SAP support for further assistance, especially if it appears to be a bug or a more complex issue.
Related Information:
By following these steps, you should be able to identify the root cause of the GG699 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
GG698
Table type & is incorrect
What causes this issue? Table type &V1& of table &V2& is incorrect. The following rules apply: Summary table: the table type must be ...
GG697
Error in index '3' of table &
What causes this issue? You must create an index for table &V1&. This index is named '3'. The index must contain the following fi...
GG700
The table definition contains errors for field &
What causes this issue? The table definition for field &V1& is incorrect. Domain &V2& has been assigned to the field. However, the do...
GG701
Table & is not defined in Special Purpose Ledger
What causes this issue? You have tried to use table &V1& as a reference table. However, this table is not known in Special Purpose Ledger.Sy...
Click on this link to search all SAP messages.