Do you have any question about this error?
Message type: E = Error
Message class: EPRO - Messages for EDM Profile Processing
Message number: 717
Message text: Replacement value proc. &1: Control meter is not unique
This procedure replaces missing values with values from the profile of
the control meter.
First, the system finds the control registers by searching for the
registers allocated to profile &v2&. The system then determines the
control register for each of the registers found. Only one control
register may be allocated to each register during a certain period.
Otherwise, this procedure cannot generate replacement values.
In this case, the system found more than one control register.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you want to use this procedure for this profile, you have to change
the relevant register relationships.
Error message extract from SAP system. Copyright SAP SE.
EPRO717
- Replacement value proc. &1: Control meter is not unique ?The SAP error message EPRO717 indicates that there is an issue with the control meter in the context of a replacement value process. Specifically, it suggests that the control meter is not unique, which means that the system has found multiple entries for the same control meter, leading to ambiguity in processing.
Cause:
- Duplicate Entries: The most common cause of this error is the presence of duplicate control meter entries in the system. This can happen if the same meter is registered multiple times or if there are inconsistencies in the data.
- Incorrect Configuration: There may be issues with the configuration of the control meters in the system, leading to non-unique identifiers.
- Data Migration Issues: If data has been migrated from another system, it is possible that duplicates were introduced during the migration process.
Solution:
Check for Duplicates:
- Use transaction codes like SE16 or SE11 to check the relevant database tables (e.g., EPRO_METER) for duplicate entries of the control meter in question.
- Identify and resolve any duplicates by either deleting or merging the entries as appropriate.
Review Configuration:
- Ensure that the configuration for control meters is set up correctly. This includes checking the settings in the relevant customizing transactions (e.g., SPRO).
- Make sure that the control meter is defined uniquely in the system.
Data Cleanup:
- If duplicates are found, perform a data cleanup to ensure that each control meter has a unique entry.
- If necessary, consult with your data management team to ensure that the integrity of the data is maintained.
Testing:
- After making changes, test the replacement value process again to ensure that the error has been resolved.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific error message for additional guidance and best practices.
Related Information:
By following these steps, you should be able to identify the cause of the EPRO717 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EPRO716
Replacement value proc. &1: Determined profiles are not compatible
What causes this issue? Replacement value procedure &v1& copies replacement values from reference profiles. You cannot use profile &v2&am...
EPRO715
Replacement value proc. &1: Determined profiles lie outside repl. period
What causes this issue? Replacement value procedure &v1& copies replacement values from reference profiles. For each value in the repalcement...
EPRO718
Replacement value proc. &1: Hist. values must agree w/replacement period
What causes this issue? This procedure uses historic values of the profile to replace missing values. You have to select the <LS>Replacement va...
EPRO719
Replacement value proc. &1: Status of determined profile values not valid
What causes this issue? You have attempted to copy replacement values from profile &v2&. However, there values in the period from &v3&...
Click on this link to search all SAP messages.