Do you have any question about this error?
Message type: E = Error
Message class: EPRO - Messages for EDM Profile Processing
Message number: 718
Message text: Replacement value proc. &1: Hist. values must agree w/replacement period
This procedure uses historic values of the profile to replace missing
values.
You have to select the <LS>Replacement value</> field and enter a
reference period in Customizing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_PENCIL OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
EPRO718
- Replacement value proc. &1: Hist. values must agree w/replacement period ?The SAP error message EPRO718 indicates that there is a mismatch between historical values and the replacement period defined for a particular process or procedure. This error typically arises in the context of SAP's Plant Maintenance (PM) or Production Planning (PP) modules, where replacement values for maintenance or production processes are being evaluated.
Cause:
The error occurs when:
- Historical Values Mismatch: The historical data (e.g., maintenance history, production history) does not align with the defined replacement period. This could mean that the historical values are either too old or too recent compared to what is expected for the replacement period.
- Configuration Issues: The configuration settings for the replacement values or periods may not be set correctly, leading to inconsistencies.
- Data Entry Errors: Incorrect data entry in the relevant fields can also lead to this error.
Solution:
To resolve the EPRO718 error, you can take the following steps:
Check Historical Values: Review the historical values associated with the process or procedure in question. Ensure that they fall within the expected range of the replacement period.
Review Replacement Period Settings: Go to the configuration settings for the replacement values and verify that the replacement period is correctly defined. Make sure it aligns with the historical data.
Adjust Data: If you find discrepancies in the historical values or the replacement period, you may need to adjust the data accordingly. This could involve updating historical records or modifying the replacement period settings.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on how to configure replacement values and periods correctly.
Testing: After making adjustments, test the process again to ensure that the error no longer occurs.
Seek Help from SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the EPRO718 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
EPRO717
Replacement value proc. &1: Control meter is not unique
What causes this issue? This procedure replaces missing values with values from the profile of the control meter. First, the system finds the control...
EPRO716
Replacement value proc. &1: Determined profiles are not compatible
What causes this issue? Replacement value procedure &v1& copies replacement values from reference profiles. You cannot use profile &v2&am...
EPRO719
Replacement value proc. &1: Status of determined profile values not valid
What causes this issue? You have attempted to copy replacement values from profile &v2&. However, there values in the period from &v3&...
EPRO720
Replacement value proc. &1: Could not determine reference consumption
What causes this issue? You must enter the reference consumption in order to replace values of profile &v2& using this procedure. For example...
Click on this link to search all SAP messages.