Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 453
Message text: No energy feeding volume found on &1 for weighting key &2
The system could not find any entries for date &v1& for the weighting
key &v2& and division category &v3& in table &v4&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Enter the parameter combination in table &v4&.
Error message extract from SAP system. Copyright SAP SE.
EL453
- No energy feeding volume found on &1 for weighting key &2 ?The SAP error message EL453 "No energy feeding volume found on &1 for weighting key &2" typically occurs in the context of energy management or utility billing within the SAP system. This error indicates that the system is unable to find the required energy feeding volume data for a specific object (like a measuring point or a contract) and a specified weighting key.
Causes:
- Missing Data: The most common cause is that there is no recorded energy feeding volume for the specified object and weighting key in the database.
- Incorrect Weighting Key: The weighting key specified may not be valid or may not correspond to any existing data.
- Configuration Issues: There may be configuration issues in the energy management module that prevent the system from retrieving the necessary data.
- Data Transfer Issues: If data is being transferred from another system or module, there may have been an error in the data transfer process.
- Timing Issues: The data may not have been updated or posted yet, especially if the system is in a transitional state.
Solutions:
- Check Data Entry: Verify that the energy feeding volume data has been correctly entered for the specified object and weighting key. Ensure that the data exists in the relevant tables.
- Validate Weighting Key: Ensure that the weighting key used in the transaction is correct and corresponds to the expected data.
- Review Configuration: Check the configuration settings in the SAP system related to energy management and ensure that they are set up correctly.
- Data Consistency Check: Run consistency checks or reports to identify any discrepancies in the data that may be causing the issue.
- Update Data: If the data is missing, you may need to enter the required energy feeding volume manually or through a batch process.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the error message and related processes.
Related Information:
By following these steps, you should be able to identify the root cause of the EL453 error and implement a solution to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
EL452
Device &1, reg. &2, MR date &3: MR date lies in an already billed period
What causes this issue? The period of the meter reading date has already been calculated. &V3& is the end of the billing period. A meter read...
EL451
Device &1, MR date &2: Date of maximum reading > actual MR date
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL454
Enter an allocation date
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL455
Schedule allocation date between &1 and &2
What causes this issue? Allocation date for meter readingSystem Response This date is used during billing and preliminary demand processing for allo...
Click on this link to search all SAP messages.