Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 387
Message text: The value in the Active field in segment number &1 in not permitted
While uploading the meter reading data with an IDoc of type
ISU_MR_UPLOAD or with BAPI_MTRREADDOC_UPLOAD, invalid values were
passed on for field <DS:DE.E_AKTIV>Active</>.
If the upload took place <ZH>via IDoc</>, the error is located in
segment &v1&.
When the upload took place <ZH>using the corresponding BAPI</>, then
&V1& is involved. Entry of the transferred tables with meter reading
data.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Correct the value.
Error message extract from SAP system. Copyright SAP SE.
EL387
- The value in the Active field in segment number &1 in not permitted ?The SAP error message EL387 indicates that there is an issue with the value in the "Active" field of a specific segment in your data. This error typically arises in the context of Electronic Data Interchange (EDI) or when dealing with IDoc processing, particularly in the area of master data or transactional data.
Cause: The error message EL387 is triggered when the value entered in the "Active" field of a segment is not allowed according to the defined rules or data structure for that segment. This could be due to: Invalid Value: The value provided does not match the expected values defined in the data structure (e.g., it might be expecting 'X' for active and ' ' for inactive).
Configuration Issues: The segment configuration in the IDoc or EDI mapping may not be set up correctly, leading to invalid values being processed. Data Integrity Issues: There may be inconsistencies in the data being sent or
Get instant SAP help. Sign up for our Free Essentials Plan.
EL386
Billing of installation &1 suppressed
What causes this issue? Billing is already planned for this installation, or even already carried out, within the interval specified for the meter re...
EL385
Billing of installation &1 will be suppressed
What causes this issue? Billing is already planned for this installation, or even already carried out, within the interval specified for the meter re...
EL388
Device &1, register &2: entry of replaced device on &3 not possible
What causes this issue? The meter reading took place after a device replacement, but the meter reading order was created before the device replacemen...
EL389
Error in access to table TE402 for allocation type &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.