Message text: Device &1, register &2: Cannot use ind.plaus.check. 96 (fixed val.dev.)
The current installation is an inactive installation.
When these types of installation are reconnected, the independent
plausibility check <SE>96 </>- <LS>Fixed value deviation check</> is
usually performed during the move-in meter reading. The system checks
here whether consumption has taken place since the customer moved out
(move-out meter reading) and whether this exceeds the maximum admissible
variation defined for this in Customizing.
In the current case, no move-out meter reading has been entered in the
system.
The system does not perform the fixed value deviation check.
To perform the fixed value deviation check, you must first enter the
move-out meter reading.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL277
- Device &1, register &2: Cannot use ind.plaus.check. 96 (fixed val.dev.) ?The SAP error message EL277 indicates an issue related to the use of the "independent plausibility check" for a specific device and register. This error typically arises in the context of device management and meter reading in SAP IS-U (Industry Solution for Utilities).
Cause:
The error message EL277 can occur due to several reasons:
- Fixed Value Device: The device in question is a fixed value device, which means it does not support independent plausibility checks. This is often the case for devices that have a fixed reading or do not change over time.
- Configuration Issues: There may be configuration settings in the device type or register that do not allow for the plausibility check to be applied.
- Data Inconsistencies: There could be inconsistencies in the data related to the device or register that prevent the plausibility check from being executed.
Solution:
To resolve the EL277 error, consider the following steps:
Check Device Type: Verify that the device type is correctly configured. If it is a fixed value device, ensure that you are not trying to apply a plausibility check that is not applicable.
Review Configuration: Check the configuration settings for the device and register in the SAP system. Ensure that the plausibility check settings are appropriate for the type of device you are working with.
Data Validation: Validate the data associated with the device and register. Look for any inconsistencies or errors in the readings that may be causing the plausibility check to fail.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling fixed value devices and plausibility checks.
Contact Support: If the issue persists after checking the above points, consider reaching out to SAP support or your internal SAP team for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
EL276
Dependent validation cannot be carried out for index no. &1, val. &2
What causes this issue? The error was caused by one of the following reasons: A previous dependent validation was classified as incorrect and thus lo...
EL275
&1 &2: Entry of meter readings not possible
What causes this issue? The error was caused by one of the following. You tried to record a meter reading for a flat-rate installation. Because no de...
EL278
Double entries for same from-date are not permissible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL279
No schedule record found for alternate portion &1 of contract &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.