Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 275
Message text: &1 &2: Entry of meter readings not possible
The error was caused by one of the following.
You tried to record a meter reading for a flat-rate installation.
Because no devices are installed in a flat-rate installation, however,
it is not possible to record meter reading results.
Meter readings were already entered today with the same meter reading
reason (usually periodic meter reading)
You cannot enter more than one meter reading on the same day with the
same meter reading reason.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Correct your entries.
To bill a flat-rate installation, generate a billing order via
<DS:TRAN.EL01>Create meter reading order</>.
Error message extract from SAP system. Copyright SAP SE.
EL275
- &1 &2: Entry of meter readings not possible ?The SAP error message EL275 indicates that the entry of meter readings is not possible due to certain conditions not being met. This error typically arises in the context of utilities management, particularly in the modules related to energy or water meter readings.
Causes of EL275 Error
Incorrect Status of the Device: The meter or device may not be in a status that allows for reading entries. For example, if the meter is marked as inactive or has been decommissioned, readings cannot be entered.
Time Frame Issues: The date for which the meter reading is being entered may be outside the allowed time frame. For instance, if the reading date is in the future or too far in the past, the system may prevent entry.
Missing Master Data: There may be missing or incomplete master data for the meter or the installation. This could include missing installation details or incorrect configuration.
Authorization Issues: The user attempting to enter the meter reading may not have the necessary permissions or roles assigned in SAP to perform this action.
Technical Issues: There could be technical issues or bugs in the SAP system that are preventing the entry of meter readings.
Solutions to EL275 Error
Check Device Status: Verify the status of the meter or device in the system. Ensure that it is active and configured correctly for reading entries.
Review Time Frame: Ensure that the date for the meter reading is within the acceptable range. If necessary, adjust the date to a valid one.
Validate Master Data: Check the master data for the meter and installation. Ensure that all required fields are filled out and that the data is accurate.
User Authorization: Confirm that the user has the appropriate authorizations to enter meter readings. If not, work with your SAP security team to obtain the necessary permissions.
Consult SAP Notes: Look for any relevant SAP Notes or patches that may address known issues related to this error message. Applying updates or fixes may resolve the problem.
System Logs and Debugging: If the issue persists, check system logs for any additional error messages or warnings that could provide more context. Debugging the transaction may also help identify the root cause.
Related Information
If the problem continues after trying the above solutions, it may be necessary to escalate the issue to your SAP support team or consult with SAP directly for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EL274
Extrapolation cannot be carried out because no inst. has been allocated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL273
Dependent validation 07: Deviation in consumption ratio
What causes this issue? In dependent validation 07, the system checks the consumption ratio of registers with different usage types against a fixed v...
EL276
Dependent validation cannot be carried out for index no. &1, val. &2
What causes this issue? The error was caused by one of the following reasons: A previous dependent validation was classified as incorrect and thus lo...
EL277
Device &1, register &2: Cannot use ind.plaus.check. 96 (fixed val.dev.)
What causes this issue? The current installation is an inactive installation. When these types of installation are reconnected, the independent plaus...