Do you have any question about this error?
Message type: E = Error
Message class: EE_QD -
Message number: 108
Message text: Dev. &1, reg. &2, chge date &3: Chge to fixed temperature &4 => Long txt
You want to make a change to the <ZH>fixed temperature</> on the
specified <ZH>change date</> (<ZH>activity day</>).
However, either no meter reading result is yet available, or the meter
reading result in question is only an <ZH>estimated</> result due to the
allocated meter reading type.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_VERARB OBJECT DOKU ID TXNote that the meter reading result must have activity day 1 as the meter
reading date.
Also see the following <DS:TX.QD_ABLESUNGEN>note</>.
Error message extract from SAP system. Copyright SAP SE.
EE_QD108
- Dev. &1, reg. &2, chge date &3: Chge to fixed temperature &4 => Long txt ?The SAP error message EE_QD108 typically relates to issues in the Quality Management (QM) module, specifically concerning the handling of fixed temperature values in quality notifications or inspection lots. The message indicates that there is a change to a fixed temperature value that is not being processed correctly.
Cause:
- Data Inconsistency: The error may arise due to inconsistencies in the data related to the temperature settings in the system.
- Configuration Issues: There may be configuration settings in the Quality Management module that are not aligned with the expected values for temperature.
- Master Data Issues: The master data for materials or inspection characteristics may not be set up correctly, leading to conflicts when processing temperature-related data.
- User Input Error: Incorrect user input during the creation or modification of quality notifications or inspection lots can trigger this error.
Solution:
- Check Configuration: Review the configuration settings in the Quality Management module to ensure that the fixed temperature values are correctly defined and aligned with the business processes.
- Validate Master Data: Ensure that the master data for materials and inspection characteristics is accurate and complete. This includes checking the temperature settings and any related parameters.
- Review Change Logs: Look at the change logs for the specific development object (Dev. &1) and registration (reg. &2) to identify any recent changes that may have led to this error.
- Correct User Input: If the error is due to user input, ensure that users are trained on the correct procedures for entering temperature values and that they are following the guidelines.
- Consult Documentation: Refer to SAP documentation or notes related to the EE_QD108 error message for any specific recommendations or patches that may address the issue.
- Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the EE_QD108 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
EE_QD107
Dev. &1, reg. &2, change date &3: Change to gas procedure &4 => Long text
What causes this issue? You want to make a change to the <ZH>gas procedure</> on the specified <ZH>change date</> (<ZH>...
EE_QD106
Device &1 Register &2 MR Date &3: Check meter reading type
What causes this issue? Due to the allocated meter reading type, the specified meter reading is only an <ZH>estimated</> meter reading re...
EE_QD109
Dev. &1, reg. &2, chge date &3: Chge to GVCF of register &4 => Long text
What causes this issue? You want to make a change to the <ZH>determined gas volume correction factor from the register</> on the specifie...
EE_QD118
Inst. &4 Dev. &1 Reg. &2 MRDate &3: Current gas data not available
What causes this issue? The meter reading result has the quantity determination status <ZH>3</> - <LS>Quantity Determination Trigge...
Click on this link to search all SAP messages.