Do you have any question about this error?
Message type: E = Error
Message class: EE_QD -
Message number: 109
Message text: Dev. &1, reg. &2, chge date &3: Chge to GVCF of register &4 => Long text
You want to make a change to the <ZH>determined gas volume correction
factor from the register</> on the specified <ZH>change date</> (<ZH>
activity day</>). The <DS:DE.USEZUSTZZW>usage type</> history should
also be taken into account.
However, either no meter reading result is yet available, or the meter
reading result in question is only an <ZH>estimated</> result due to the
allocated meter reading type.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_VERARB OBJECT DOKU ID TXNote that the meter reading result must have activity day 1 as the meter
reading date.
Also see the following <DS:TX.QD_ABLESUNGEN>note</>.
Error message extract from SAP system. Copyright SAP SE.
EE_QD109
- Dev. &1, reg. &2, chge date &3: Chge to GVCF of register &4 => Long text ?The SAP error message EE_QD109 typically relates to issues in the configuration or processing of the General Value Chain Framework (GVCF) in the context of development and change management. This error message indicates that there is a change to the GVCF of a specific register, which may not be properly handled or may have inconsistencies.
Cause:
- Configuration Issues: The error may arise from incorrect or incomplete configuration settings in the GVCF or related registers.
- Data Inconsistencies: There may be inconsistencies in the data associated with the registers, such as missing or incorrect entries.
- Change Management: The error could be triggered by changes made to the GVCF that are not properly reflected in the associated registers.
- Authorization Issues: Sometimes, the user may not have the necessary authorizations to make changes to the GVCF or the registers.
Solution:
- Check Configuration: Review the configuration settings for the GVCF and the specific register mentioned in the error message. Ensure that all required fields are correctly filled out.
- Data Validation: Validate the data associated with the registers to ensure there are no inconsistencies or missing entries. Correct any discrepancies found.
- Review Change Logs: Look at the change logs for the GVCF and the register to identify any recent changes that may have caused the issue. Revert or correct any problematic changes if necessary.
- Authorization Check: Ensure that the user has the necessary authorizations to make changes to the GVCF and the registers. If not, contact your system administrator to obtain the required permissions.
- Consult Documentation: Refer to SAP documentation or support notes related to the EE_QD109 error for specific guidance and troubleshooting steps.
- Contact SAP Support: If the issue persists after trying the above solutions, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the EE_QD109 error and implement an appropriate solution.
Get instant SAP help. Start your 7-day free trial now.
EE_QD108
Dev. &1, reg. &2, chge date &3: Chge to fixed temperature &4 => Long txt
What causes this issue? You want to make a change to the <ZH>fixed temperature</> on the specified <ZH>change date</> (<ZH...
EE_QD107
Dev. &1, reg. &2, change date &3: Change to gas procedure &4 => Long text
What causes this issue? You want to make a change to the <ZH>gas procedure</> on the specified <ZH>change date</> (<ZH>...
EE_QD118
Inst. &4 Dev. &1 Reg. &2 MRDate &3: Current gas data not available
What causes this issue? The meter reading result has the quantity determination status <ZH>3</> - <LS>Quantity Determination Trigge...
EE_QD119
Inst. &4 Dev. &1 Reg. &2 MRDate &3: No unique previous MR doc.
What causes this issue? The meter reading result has the quantity determination status <ZH>3</> - <LS>Quantity Determination Trigge...
Click on this link to search all SAP messages.