Message type: E = Error
Message class: EE_QD -
Message number: 106
Message text: Device &1 Register &2 MR Date &3: Check meter reading type
Due to the allocated meter reading type, the specified meter reading is
only an <ZH>estimated</> meter reading result.
To allow quantity determination to take place correctly, any changes to
the following points, which play an important role in the <ZH>
determination of gas factors</>, must be accompanied by <ZH>actual</>
meter reading results:
Gas procedure
Fixed temperature
Volume correction factor (from register)
Quantity determination and validation across such procedures are not
consistently possible for <DS:DE.E_QD_PROC>quantity determination
procedure</> <EX>03</>- <LS>Quantity Determination During Meter Reading
</>.
For technical reasons, the system can only issue a warning here.
Check the meter reading type.
For the cases listed above, provide <ZH>actual</> meter readings.
<ZH><ZU><ZK>Alternative</></></>
If you cannot provide acutal meter readings, you still have to <ZK>
formally declare the meter reading as an actual meter reading</>for the
cases listed above.
You can create a <DS:DE.ISTABLART>user-defined meter reading type</>
with <DS:DE.ABLESTYP>meter reading category</> 01 in table TE436 and
enter a suitable text
<ZK>to explain that this is a special case.</>
<ZK>This means you can use the estimation function, but you have to give
the result this user-defined meter reading type.</>
<ZK><ZH><ZU>Comment</></></>
<ZK>The fields listed above are used primarily in the following
transactions:</>
<ZK>EG70 Change Rate Data</>
<ZK>EC30 Maintain Rate Data</>
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EE_QD106
- Device &1 Register &2 MR Date &3: Check meter reading type ?The SAP error message EE_QD106 typically relates to issues with meter readings in the SAP IS-U (Industry Solution for Utilities) module. This error indicates that there is a problem with the meter reading type associated with a specific device and register. Here’s a breakdown of the cause, potential solutions, and related information:
Cause:
- Invalid Meter Reading Type: The meter reading type specified for the device and register may not be valid or may not be configured correctly in the system.
- Configuration Issues: There may be configuration issues in the meter reading type settings, such as missing or incorrect entries in the relevant tables.
- Data Entry Errors: The user may have entered an incorrect meter reading type when attempting to record a meter reading.
- Device/Registration Issues: The device or register may not be properly set up in the system, leading to inconsistencies.
Solution:
Check Meter Reading Type: Verify the meter reading type associated with the device and register. Ensure that it is valid and correctly configured in the system.
- Navigate to the relevant configuration settings in SAP (Transaction Codes like OIS2 for meter reading types).
Review Configuration: Check the configuration of the meter reading type in the system. Ensure that all necessary settings are in place and that the meter reading type is active.
- Ensure that the meter reading type is assigned to the correct device type and that it is allowed for the specific register.
Correct Data Entry: If the error was triggered by user input, ensure that the correct meter reading type is being used when entering the meter reading.
- Validate the input against the list of valid meter reading types.
Check Device and Register Setup: Ensure that the device and register are properly set up in the system. This includes checking the master data for the device and ensuring that it is linked to the correct meter reading type.
Consult Documentation: Refer to SAP documentation or help resources for additional guidance on configuring meter reading types and troubleshooting related issues.
Related Information:
Transaction Codes: Familiarize yourself with relevant transaction codes such as:
SAP Notes: Check for any SAP Notes related to this error message for patches or updates that may resolve the issue.
User Roles and Authorizations: Ensure that the user has the necessary authorizations to perform actions related to meter readings and configurations.
Testing: After making changes, conduct tests to ensure that the issue is resolved and that meter readings can be recorded without errors.
If the problem persists after following these steps, it may be beneficial to consult with an SAP specialist or your organization's SAP support team for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EE_QD105
Quantity determination called for &1 triggers, &2 successful
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EE_QD104
Internal error: New quantity determination cannot be executed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EE_QD107
Dev. &1, reg. &2, change date &3: Change to gas procedure &4 => Long text
What causes this issue? You want to make a change to the <ZH>gas procedure</> on the specified <ZH>change date</> (<ZH>...
EE_QD108
Dev. &1, reg. &2, chge date &3: Chge to fixed temperature &4 => Long txt
What causes this issue? You want to make a change to the <ZH>fixed temperature</> on the specified <ZH>change date</> (<ZH...