Message type: E = Error
Message class: EAMS_BO - Business Object Layer
Message number: 263
Message text: Counter reading for point &1 higher than in previous doc. &2: &3 &4
A counter overflow reading has not been defined for the measuring point,
and the counter reading that you have entered is greater than the one in
the last measurement document.
This is not allowed as the counter has been defined as running
backwards. If this is the first measurement document entered for the
backward counter, you can set the Total Counter Reading externally via
TA IK11.
Processing will not be continued.
Check your entries or check the measuring point counter data.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EAMS_BO263
- Counter reading for point &1 higher than in previous doc. &2: &3 &4 ?The SAP error message EAMS_BO263 indicates that there is a discrepancy in the counter readings for a specific point. This error typically occurs in the context of Asset Management or Plant Maintenance when trying to record a new counter reading that is higher than the previous recorded value. Here’s a breakdown of the cause, potential solutions, and related information:
Cause:
- Counter Reading Validation: The system validates that the new counter reading must be greater than or equal to the last recorded reading. If the new reading is lower, the system will throw this error.
- Data Entry Error: The user may have mistakenly entered an incorrect counter reading.
- System Configuration: There may be issues with how the counter readings are configured in the system, leading to incorrect validations.
- Missing Previous Document: The previous document referenced in the error message may not exist or may not have been processed correctly.
Solution:
- Verify Counter Reading: Check the counter reading you are trying to enter against the last recorded reading. Ensure that the new reading is indeed higher than the previous one.
- Correct Data Entry: If the new reading is incorrect, re-enter the correct value that is higher than the previous reading.
- Review Previous Document: Look into the previous document referenced in the error message to ensure it is correct and has been processed properly.
- Consult Documentation: If you are unsure about the readings, consult the documentation or guidelines for the specific equipment or asset to ensure compliance with expected values.
- System Configuration Check: If the issue persists, check the configuration settings for counter readings in the SAP system. This may require assistance from a system administrator or SAP consultant.
- User Training: Ensure that users entering counter readings are adequately trained to avoid data entry errors.
Related Information:
By following these steps, you should be able to resolve the EAMS_BO263 error and ensure that counter readings are accurately recorded in the system.
Get instant SAP help. Start your 7-day free trial now.
EAMS_BO262
Counter reading for point &1 lower than in previous doc. &2: &3 &4
What causes this issue? A counter overflow reading has not been defined for the measuring point, and the counter reading that you have entered is sma...
EAMS_BO261
Counter reading for point &3 higher than in subsequent doc. &2: &1 &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EAMS_BO264
Meas. reading for point &1 outside the meas. range limits: &2 - &3 &4
What causes this issue? You have entered a measurement reading that lies outside the measurement range limits of the measuring point.System Response ...
EAMS_BO265
Cntr reading for point &1 falls above max. total cntr reading: &2 &3
What causes this issue? The counter reading or counter reading difference entered would lead to a reading greater than the maximum total counter read...
Click on this link to search all SAP messages.