Message type: E = Error
Message class: EAMS_BO - Business Object Layer
Message number: 262
Message text: Counter reading for point &1 lower than in previous doc. &2: &3 &4
A counter overflow reading has not been defined for the measuring point,
and the counter reading that you have entered is smaller than the one in
the last measurement document.
This is not allowed as the counter has not been defined as running
backwards.
Processing will not be continued.
Check your entries or check the measuring point counter data.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EAMS_BO262
- Counter reading for point &1 lower than in previous doc. &2: &3 &4 ?The SAP error message EAMS_BO262 indicates that there is an issue with the counter reading for a specific point. The message states that the counter reading for the specified point (denoted as &1) is lower than the reading recorded in a previous document (denoted as &2). The additional information (&3 and &4) typically provides further context, such as the specific counter reading values or other relevant details.
Cause:
The primary cause of this error is that the new counter reading is less than the last recorded reading for that point. This situation can occur due to several reasons, including:
To resolve this error, you can take the following steps:
Verify the Counter Readings: Check the current and previous counter readings for the specified point. Ensure that the readings are accurate and reflect the actual usage or measurement.
Correct the Entry: If the new reading is indeed incorrect (e.g., due to a data entry mistake), correct the reading to a value that is greater than or equal to the previous reading.
Review Documentation: If the counter was reset or adjusted, ensure that all necessary documentation is in place to reflect this change. This may involve creating a new document that properly records the reset.
Consult with Relevant Personnel: If you are unsure about the readings or the process, consult with colleagues or supervisors who are familiar with the counter's operation and the data entry process.
Check Configuration: In some cases, the configuration of the counter in SAP may need to be reviewed to ensure it is set up correctly to handle readings.
Use Transaction Codes: Utilize relevant transaction codes (like IW41 for confirmation) to make the necessary adjustments or corrections.
By following these steps, you should be able to resolve the EAMS_BO262 error and ensure that counter readings are accurately recorded in the system.
Get instant SAP help. Start your 7-day free trial now.
EAMS_BO261
Counter reading for point &3 higher than in subsequent doc. &2: &1 &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EAMS_BO260
Counter reading for point &1 must be lower than counter overflow: &2 &3
What causes this issue? You are trying to enter a counter reading that is greater than the counter overflow reading.System Response Processing will ...
EAMS_BO263
Counter reading for point &1 higher than in previous doc. &2: &3 &4
What causes this issue? A counter overflow reading has not been defined for the measuring point, and the counter reading that you have entered is gre...
EAMS_BO264
Meas. reading for point &1 outside the meas. range limits: &2 - &3 &4
What causes this issue? You have entered a measurement reading that lies outside the measurement range limits of the measuring point.System Response ...
Click on this link to search all SAP messages.