Message type: E = Error
Message class: EAMS_BO - Business Object Layer
Message number: 265
Message text: Cntr reading for point &1 falls above max. total cntr reading: &2 &3
The counter reading or counter reading difference entered would lead to
a reading greater than the maximum total counter reading.
You can define the message category (error/warning) in Customizing for
each measuring point category. The message category controls whether or
not you can ignore the message and continue processing.
Check your entries.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message EAMS_BO265 indicates that the counter reading for a specific point exceeds the maximum allowed total counter reading. This error typically occurs in the context of Asset Management or Plant Maintenance when dealing with measuring points or counters.
Cause: The error arises when the counter reading you are trying to enter for a measuring point exceeds the predefined maximum limit set for that measuring point. This limit is usually defined in the configuration of the measuring point or counter in the system.
Solution: To resolve this error, you can take the following steps: Check the Maximum Counter Reading: Navigate to the configuration settings for the measuring point or counter in SAP. Verify the maximum total counter reading that has been set for the specific measuring point. Adjust the Counter Reading: If the reading you are trying to enter exceeds the maximum limit, you will need to either: Enter a lower counter reading that is within the allowed
Get instant SAP help. Sign up for our Free Essentials Plan.
EAMS_BO264 Meas. reading for point &1 outside the meas. range limits: &2 - &3 &4
What causes this issue? You have entered a measurement reading that lies outside the measurement range limits of the measuring point.System Response ...
EAMS_BO263 Counter reading for point &1 higher than in previous doc. &2: &3 &4
What causes this issue? A counter overflow reading has not been defined for the measuring point, and the counter reading that you have entered is gre...
EAMS_BO266 Cntr reading for point &1 falls below min. total cntr reading: &2 &3
What causes this issue? The counter reading or counter reading difference entered would lead to a reading less than the minimum total counter reading...
EAMS_BO270 No task list exists for technical object &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...