Message type: E = Error
Message class: CM_EHFND_FW_WFF - Messages for Exception Obj. of EHS/PS&S Workflow Foundation
Message number: 309
Message text: Defined PCBO can not be instantiated
The referenced PCBO is declared <ZK>abstract</> or contains errors that
prevent it from being instantiated.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Make sure that the method<LB>
if_ehfnd_wff_pco~get_process_control_bo_key</> returns the key of a
Business Object that inherits from the base PCBO EHFND_PROC_CTRL and is
instantiable.
Error message extract from SAP system. Copyright SAP SE.
CM_EHFND_FW_WFF309
- Defined PCBO can not be instantiated ?The SAP error message CM_EHFND_FW_WFF309 ("Defined PCBO can not be instantiated") typically occurs in the context of SAP's Flexible Workflow functionality, particularly when dealing with Process Control Business Objects (PCBOs). This error indicates that there is an issue with the instantiation of a defined PCBO, which is necessary for the workflow to function correctly. Causes:
Configuration Issues: The PCBO may not be properly configured in the system. This could include missing or incorrect settings in the workflow configuration. Missing Dependencies: The PCBO might depend on other objects or configurations that are not present or are incorrectly set up. Authorization Issues: The user or process trying to instantiate the PCBO may not have the necessary authorizations. Technical Errors: There could be underlying technical issues, such as problems with the database or application server. Solutions: Check Configuration: Review the configuration of the PCBO in the SAP system. Ensure that all required settings are correctly defined. Navigate to the relevant configuration
Get instant SAP help. Sign up for our Free Essentials Plan.
CM_EHFND_FW_WFF308
Defined PCBO does not inherit from the base PCBO
What causes this issue? The process control business object that is returned by the PCO class does not inherit directly or indirectly from the base p...
CM_EHFND_FW_WFF307
PCO Class does not return a valid key for the PCBO
What causes this issue? The process definition defines a PCO class that does not return a key of a valid process control business object. INCLUDE FND...
CM_EHFND_FW_WFF310
No workflow template associated to the PCO class
What causes this issue? No workflow templates are associated with the PCO class. The workflow template defines the steps that should be executed duri...
CM_EHFND_FW_WFF311
Event linkage to workflow template &1 not active
What causes this issue? The event link between the persistent object reference class &V2& and the workflow template &V1& is not activ...
Click on this link to search all SAP messages.