Message type: E = Error
Message class: CM_EHFND_FW_WFF - Messages for Exception Obj. of EHS/PS&S Workflow Foundation
Message number: 307
Message text: PCO Class does not return a valid key for the PCBO
The process definition defines a PCO class that does not return a key of
a valid process control business object.
INCLUDE FND_PCO_CLASS_MESSAGES OBJECT DOKU ID TX
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
In the Customizing activity <LS>Specify Process Definitions</>, enter a
valid PCO class in your process.
Make sure that the method
<LB>if_ehfnd_wff_pco~get_process_control_bo_key</> of the class returns
a key of a valid process control business object.
Error message extract from SAP system. Copyright SAP SE.
CM_EHFND_FW_WFF307
- PCO Class does not return a valid key for the PCBO ?The SAP error message CM_EHFND_FW_WFF307 indicates that there is an issue with the PCO (Process Control Object) class not returning a valid key for the PCBO (Process Control Business Object). This error typically arises in the context of SAP's Workflow Framework, particularly when dealing with process control and business object integration.
Cause: Incorrect Configuration: The PCO class may not be properly configured or may not be implemented correctly, leading to the failure in returning a valid key. Missing or Incomplete Data: The data required for the PCO class to function correctly may be missing or incomplete. Authorization Issues: There may be authorization issues preventing the PCO class from accessing the necessary data. Custom Code Issues: If there are custom implementations or enhancements, they may not be functioning as expected, leading to this error. System Bugs: There could be bugs in the SAP system or specific patches that need to be applied.
Solution: Check Configuration: Review the configuration of
Get instant SAP help. Sign up for our Free Essentials Plan.
CM_EHFND_FW_WFF306
PCO Class cannot be instantiated
What causes this issue? The process definition defines a PCO class that cannot be instantiated. INCLUDE FND_PCO_CLASS_MESSAGES OBJECT DOKU ID TXSyste...
CM_EHFND_FW_WFF305
PCO Class does not implement the required interface IF_EHFND_WFF_PCO
What causes this issue? The process definition defines a PCO class that does not implement the required interface IF_EHFND_WFF_PCO. INCLUDE FND_PCO_C...
CM_EHFND_FW_WFF308
Defined PCBO does not inherit from the base PCBO
What causes this issue? The process control business object that is returned by the PCO class does not inherit directly or indirectly from the base p...
CM_EHFND_FW_WFF309
Defined PCBO can not be instantiated
What causes this issue? The referenced PCBO is declared <ZK>abstract</> or contains errors that prevent it from being instantiated.System...
Click on this link to search all SAP messages.