Message type: E = Error
Message class: BIL - General billing
Message number: 108
Message text: Gas factor &1 cannot be defined uniquely
During <ZH>determination of the gas factor</>, the following error
occurred: It was not possible to determine the gas factor <ZH>uniquely
</>.
To avoid inconsistencies, the system terminates processing.
Check whether you have entered <ZH>all required</> meter readings using
the <ZH>correct meter reading category</> for a device. See the
following notes. If you are unable to solve the problem after reading
these, please contact SAP.
<ZH><ZU><ZK>Comments</></></>
<ZK>For <DS:DE.E_QD_PROC>quantity determination procedure</> 03 -
Quantity Determination During Meter Reading, it is very important that a
<ZH>unique</> </><ZH><ZK>gas factor can be determined</></> for the
<ZK>period between a meter reading and the previous meter reading.</>
<ZK>This includes not changing the </><ZH><ZK>gas procedure</></><ZK>
during this period unless an additional </><ZH><ZK>actual</></><ZK>meter
reading is available for the proration time ( activity day- 1 ).</>
<ZK>The gas procedure implemented must also be set up so that it does
not produce historical factors during this period. This means that you
usually require gas procedures whose components are calculated by </>
<ZH><ZK>averaging</></><ZK> or by using</><ZH><ZK>constant factors</></>
<ZK>.</>
<ZK>If you change the fields </><ZH><ZK>Gas Procedure,</></><ZK> </><ZH>
<ZK>Fixed Temperature</></><ZK>and </><ZH><ZK>Volume Correction Factor
</></><ZK> ( from register), which you change using the transactions
<ZH>EG70</> or <ZH>EC30</>, you also require </><ZH><ZK>actual</></><ZK>
meter readings.</>
<ZK>For additional notes about using the correct meter reading type, see
the long text for the following message <DS:NA.EE_QD106>EE_QD 106</></>
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BIL108
- Gas factor &1 cannot be defined uniquely ?The SAP error message BIL108, which states "Gas factor &1 cannot be defined uniquely," typically occurs in the context of billing or measurement documents in the SAP system, particularly when dealing with gas measurement and billing processes. This error indicates that the system is unable to determine a unique gas factor for the specified gas type or measurement point.
Cause:
The error can arise due to several reasons:
- Multiple Entries: There may be multiple entries for the same gas factor in the relevant configuration tables, leading to ambiguity.
- Missing Configuration: The gas factor may not be properly configured in the system, or the necessary master data may be incomplete.
- Incorrect Data: There could be incorrect or inconsistent data in the master data or transaction data related to gas measurement.
- Versioning Issues: If there are different versions of gas factors defined for the same period, the system may not be able to determine which one to use.
Solution:
To resolve the BIL108 error, you can take the following steps:
Check Configuration:
- Go to the relevant configuration settings in SAP (usually in the area of gas measurement or billing).
- Ensure that the gas factors are defined correctly and uniquely for the relevant gas types and measurement points.
Review Master Data:
- Check the master data for the gas measurement points and ensure that there are no duplicate entries for the gas factor.
- Ensure that all necessary fields are filled out correctly.
Data Consistency:
- Run consistency checks on the data to identify any discrepancies or duplicates.
- Use transaction codes like SE16 or SE11 to view the relevant tables and check for duplicate entries.
Update or Delete Duplicates:
- If you find duplicate entries, you may need to update or delete them to ensure that each gas factor is unique.
Consult Documentation:
- Refer to SAP documentation or help notes related to gas measurement and billing for any specific guidelines or troubleshooting steps.
Contact Support:
- If the issue persists after checking the above points, consider reaching out to SAP support or your internal SAP team for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the BIL108 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
BIL107
Conversion to an interim dimension not possible with QD procedure &1
What causes this issue? You are using a variant program to determine a quantity with an interim dimension. However, this is not possilbe with the cur...
BIL106
Dynam.period control not admissible for quantity determination proc.&1
What causes this issue? The rate category &v2& uses dynamic period control (DPC). The installation contains devices with quantity determinati...
BIL109
Enter a rate type that has the same rounding type
What causes this issue? Different rounding types were found for the register in installations &v1& and &v2& for the period from &...
BIL110
Specify a schema with a conditional billing program
What causes this issue? You have specified in rate category &v2& that a conditional billing program can be executed. However, the schema &...
Click on this link to search all SAP messages.