Do you have any question about this error?
Message type: E = Error
Message class: BIL - General billing
Message number: 030
Message text: Active power loss at power transformer &1 exceeds the maximum value
An active loss of &v4& kWh was calculated for power transformer device
&v1& in the period from &v2& to &v3&. This value exceeds the
<DS:DE.TLOSS_MAX_A>maximum active loss allowed</> in table
<DS:SIMG._ISUBISFTLOSSPARAM>TLOSSPARAM</>.
The system cancels billing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BIL030
- Active power loss at power transformer &1 exceeds the maximum value ?The SAP error message BIL030, which indicates that the active power loss at a power transformer exceeds the maximum value, typically arises in the context of SAP's Industry Solution for Utilities (IS-U) or in the context of energy management systems. This error is related to the monitoring and management of power transformers within the system.
Cause:
- Configuration Issues: The transformer may not be configured correctly in the system, leading to incorrect calculations of power loss.
- Data Input Errors: Incorrect or unrealistic data inputs regarding the transformer's specifications, such as capacity, efficiency, or load conditions.
- Operational Conditions: The actual operational conditions of the transformer may exceed the designed limits, possibly due to unexpected load increases or faults in the system.
- Threshold Settings: The maximum allowable power loss threshold may be set too low for the specific transformer or operational context.
Solution:
- Review Configuration: Check the configuration settings for the transformer in the SAP system. Ensure that all parameters, such as rated power, efficiency, and loss values, are correctly set.
- Validate Data Inputs: Ensure that the data entered into the system regarding the transformer is accurate and reflects the actual operational conditions.
- Adjust Thresholds: If the maximum allowable power loss is set too low, consider adjusting this threshold to a more realistic value based on the transformer's specifications and operational history.
- Monitor Operational Conditions: Investigate the operational conditions of the transformer. If there are unexpected load increases, consider whether the transformer is being overloaded and if additional capacity is needed.
- Consult Documentation: Refer to SAP documentation or support resources for specific guidance on handling this error message, as there may be additional context or steps specific to your implementation.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with SAP support or a specialist in SAP IS-U for further assistance.
Get instant SAP help. Start your 7-day free trial now.
BIL029
Transformer device &1 has the rating &2
What causes this issue? The system found power transformers with a <DS:DE.E_RATING>rating</> of zero.System Response The system issues a...
BIL028
Device &1, register &2 is allocated to an inactive transformer
What causes this issue? You tried to allocate a consumption value on register &v2& for device &v1&, which is greater than zero, to a ...
BIL031
Reactive power loss at power transformer &1 exceeds the maximum value
What causes this issue? A reactive loss of &v4& kvarh was calculated for power transformer device &v1& in the period from &v2&...
BIL032
Incorrect interval for simulation &1 - &2 for contract &3 in BAdI &4
What causes this issue? The BAdI method returned an incorrect interval for the simulation. This can have one of the following reasons: Billing docume...
Click on this link to search all SAP messages.