Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 361
Message text: Unknown register category &1 include &2 routine &3 in quantity conversion
An internal error occurred during quantity conversion in include &v2&,
routine &v3&. Register category &v1& is not supported there yet.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_SAP OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
AJ361
- Unknown register category &1 include &2 routine &3 in quantity conversion ?The SAP error message AJ361, which states "Unknown register category &1 include &2 routine &3 in quantity conversion," typically occurs during the processing of quantity conversions in SAP. This error indicates that the system has encountered an unrecognized register category while trying to perform a conversion.
Cause:
- Incorrect Configuration: The error may arise from incorrect or incomplete configuration in the quantity conversion settings. This could involve missing or misconfigured entries in the relevant tables or settings.
- Custom Code Issues: If there are custom enhancements or modifications in the quantity conversion routines, they may not be properly defined or may reference non-existent categories.
- Data Issues: There may be issues with the data being processed, such as invalid or unexpected values that do not match the expected categories.
Solution:
Check Configuration:
- Review the configuration settings for quantity conversion in the relevant transaction codes (e.g., OMT3, OMT4).
- Ensure that all necessary register categories are defined and correctly configured.
Review Custom Code:
- If there are custom routines or enhancements, check the code for any references to register categories that may not exist.
- Ensure that any custom logic adheres to the expected structure and definitions.
Data Validation:
- Validate the data being processed to ensure that it conforms to the expected formats and values.
- Check for any inconsistencies or anomalies in the data that could lead to this error.
Debugging:
- If the issue persists, consider debugging the program or routine that is generating the error. This can help identify the exact point of failure and the context in which the unknown register category is being referenced.
SAP Notes:
- Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates that resolve known issues related to quantity conversion.
Consult Documentation:
- Review SAP documentation related to quantity conversion and register categories to ensure compliance with best practices.
Related Information:
By following these steps, you should be able to identify the root cause of the AJ361 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
AJ360
Error occurred in quantity conversion when grouping together time slices
What causes this issue? An internal error occurred in billing during quantity conversion for device &v1&, register &v2&. The conversi...
AJ359
Error occurred in quantity conversion regarding number of conversions
What causes this issue? An internal error occurred in billing during quantity conversion for device &v1&, register &v2&. The conversi...
AJ362
Not possible to balance rounding in quantity conversion
What causes this issue? During the quantity conversion, rounding could not be balanced for entries corresponding to reference number &v1& in ...
AJ363
No entry in &4 for logical register &1 from &2 to &3
What causes this issue? An internal error occurred in include LEUMWAF01, routine CONV_EXEC. For logical register &v1& from &v2& to &a...
Click on this link to search all SAP messages.