How To Fix PYC_CONF_WB070 - Valor semántico & rechazado para definición de regla de validación filtro


SAP Error Message - Details

  • Message type: E = Error

  • Message class: PYC_CONF_WB -

  • Message number: 070

  • Message text: Valor semántico & rechazado para definición de regla de validación filtro

  • Show details Hide details
  • ¿Qué causa este problema?

    This validation rule is used as filter by other validation rules to
    suppress their alerts. You see this message because the semantic value
    for semantic category <AB>PYD_CKFLTR </>for the filter validation rule
    is not the validation rule ID.
    <ZH>Background</>
    One validation rule X can be used as filter to suppress the check
    results of other validation rules (Y and Z for example). As a result, if
    an alert detected by Y and Z is already raised by validation rule X, the
    same alert will not be shown by Y and Z.
    Prior to Configuration Workbench, this is implemented in Customizing
    activity Define Check Types (under Customizing for <LS>Payroll ->
    Payroll International -> Payroll Control Center -> Payroll Control
    Center Configuration Simplification</>.)
    For validation rule X, which is used as filter, assign the semantic
    category <AB>PYD_CKFLTR </>and any pairing semantic value (for example,
    ABCD).
    For validation rules Y and Z, which use validation rule X as filter,
    assign the semantic category <AB>PYD_NEED </>and the same pairing value
    (ABCD in this case).
    RESET N1
    In Configuration Workbench, this is implemented by configuring alert
    dependencies for validation rules:
    Enable validation rule X as a filter by selecting the checkbox <LS>This
    validation rule can be used by other validation rules to suppress raised
    alerts </>on the <LS>Alert Dependencies </>tab page.
    Add validation rule X in the alert dependencies of validation rules Y
    and Z on the <LS>Alert Dependencies </>tab page.
    With Configuration Workbench, you no longer need to enter a pairing
    value, but the validation rule ID is used automatically as the semantic
    value for <AB>PYD_CKFLTR</> if the validation rule is used as a filter.

    Respuesta del sistema

    This custom-paring-value implementation in Customizing activity is now
    deprecated with the introduction of Configuration Workbench. With
    Configuration Workbench, the pairing value is the ID of the filter
    validation rule.
    The <LS>Consistency Check for Existing Objects with Configuration
    Workbench </>(<AB>PYC_SUPPORT_CWB_CONS_CHECK</>) report can update the
    configuration by doing the following:
    RESET N1
    For filter validation rule X, change from <AB>PYD_CKFLTR = ABCD </>to
    <AB>PYD_CKFLTR = ID of filter validation rule X</>.
    Find all validation rules with <AB>PYD_NEED = ABCD</>. In this example,
    they are validation rules Y and Z.
    Check whether there are other validation rules (W, for example) that
    provides a filter by using the same pairing key ABCD: <AB>PYD_CKFLTR =
    ABCD</>.
    If yes, for validation rules Y and Z, change from <AB>PYD_NEED = ABCD
    </>to <AB>PYD_NEED = ID of filter validation rule X</>.
    If no other filter validation rules use the same pairing value
    <AB>PYD_CKFLTR = ABCD</>, then for validation rules Y and Z, change from
    <AB>PYD_NEED = ABCD </>to <AB>PYD_NEED = ID of filter validation rule X
    </> and delete the entry <AB>PYD_NEED = ABCD</>.
    <ZH>Result</>
    Validation rule X is still used as filter by relevant validation rules.
    But now the pairing semantic value is the ID of the filter validation
    rule X rather than a custom semantic value. This is the required logic
    of Configuration Workbench.

    ¿Cómo arreglar este error?

    (Recommended) If you want the report to apply the abovementioned
    solution for you, choose <LS>Apply Solution </>in the application
    toolbar bar on the <LS>Display All Convertible Configurations </>page of
    the report.
    If you want to change the configuration by yourself, you can manually
    edit alert dependencies for relevant validation rules in Configuration
    Workbench or edit the semantic values of relevant validation rules in
    Customizing activity <LS>Define Check Types</>.

    Procedimiento para Administradoras de Sistemas

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.


    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


Smart SAP Assistant

  • ¿Cuál es la causa y la solución del error de SAP PYC_CONF_WB070 - Valor semántico & rechazado para definición de regla de validación filtro ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant