Message text: Valor semántico &1 obsoleto para dependencia de alerta
You see this message because the semantic value for semantic category
<AB>PYD_NEED </>for the validation rule is not the ID of a filter
validation rule.
<ZH>Background</>
One validation rule Y can use another validation rule X as filter to
suppress the check results of Y. As a result, if an alert detected by Y
is already raised by validation rule X, the same alert will not be shown
by Y.
Prior to Configuration Workbench, this is implemented in Customizing
activity Define Check Types (under Customizing for <LS>Payroll ->
Payroll International -> Payroll Control Center -> Payroll Control
Center Configuration Simplification</>.)
For validation rule X, which is used as filter, assign the semantic
category <AB>PYD_CKFLTR </>and any pairing semantic value (for example,
ABCD).
For validation rule Y, which uses validation rule X as filter, assign
the semantic category <AB>PYD_NEED </>and the same pairing value (ABCD
in this case).
RESET N1
In Configuration Workbench, this is implemented by configuring alert
dependencies for validation rules:
Enable validation rule X as a filter by selecting the checkbox <LS>This
validation rule can be used by other validation rules to suppress raised
alerts </>on the <LS>Alert Dependencies </>tab page.
Add validation rule X in the alert dependencies of validation rule Y on
the <LS>Alert Dependencies </>tab page.
With Configuration Workbench, you no longer need to enter a pairing
value, but the validation rule ID is used automatically as the semantic
value for <AB>PYD_CKFLTR</> if the validation rule is used as a filter.
Solution
This custom-paring-value implementation in Customizing activity is now
deprecated with the introduction of Configuration Workbench. With
Configuration Workbench, the pairing value is by default the ID of the
filter validation rule.
The <LS>Consistency Check for Existing Objects with Configuration
Workbench </>(<AB>PYC_SUPPORT_CWB_CONS_CHECK</>) report can update the
configuration by doing the following:
RESET N1
Find all the validation rules that are being used by validation rule Y (
<AB>PYD_NEED = ABCD</>) as filter.
The system checks all validation rules with <AB>PYD_CKFLTR</> <AB>= ABCD
</>.
Change the semantic value of <AB>PYD_NEED = ABCD</> for validation rule
Y to <AB>PYD_NEED = ID of each filter validation rule</>.
For each filter validation rule, change the semantic value of
<AB>PYD_CKFLTR</> <AB>= ABCD </>to <AB>PYD_CKFLTR</> <AB>= ID of filter
validation rule</>.
<ZH>Result</>
Validation rule Y still uses validation rule X as filter. But now the
pairing semantic value is the ID of the filter validation rule X rather
than a custom semantic value. This is the required logic of
Configuration Workbench.
(Recommended) If you want the report to apply the abovementioned
solution for you, choose <LS>Apply Solution </>in the application
toolbar bar on the <LS>Display All Convertible Configurations </>page of
the report.
If you want to change the configuration by yourself, you can manually
edit alert dependencies for relevant validation rules in Configuration
Workbench or edit the semantic values of relevant validation rules in
Customizing activity <LS>Define Check Types</>.
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
PYC_CONF_WB069
- Valor semántico &1 obsoleto para dependencia de alerta ?Get instant SAP help. Start your 7-day free trial now.
PYC_CONF_WB066
No tiene autorización para tratar objetos
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error. Procedimiento para Administra...
PYC_CONF_WB065
No tiene autorización para utilizar el workbench de configuración
¿Qué causa este problema? The authorization for accessing Configuration Workbench and editing objects in it is controlled by the authorization obje...
PYC_CONF_WB070
Valor semántico & rechazado para definición de regla de validación filtro
validation rule can be used by other validation rules to suppress raised alerts </>on the <LS>Alert Dependencies </>tab page. Add v...
PYC_CONF_WB071
País/Región &1 de regla de validación &2 inconsistente con directriz
¿Qué causa este problema? The validation rule must have the same country/region as the policy that the validation rule is assigned to. This message...