Do you have any question about this error?
Message type: E = Error
Message class: CLBW_META - For Generating Metadata
Message number: 020
Message text: InfoObjeto Basis/Fuente &1 no relevante (consulte texto explicativo)
When creating an InfoSource for classification or configuration data in
the BW system, the key fields of the basic InfoSource that are linked to
key fields of a OLTP basic DataSource are transferred into the
extraction structure. This only occurs if the key fields of this OLTP
basic DataSource have the same names as the key fields of the
classification DataSource.
For example: a classification DataSource in the OLTP system 1CL_OMAT001
has the same key field as its corresponding basis DataSource (MATNR).
This basis DataSource is linked to a base InfoSource from the BW system
via the key field assignment, for example, MATNR <-> 0MATERIAL. In the
extraction structure of the classification InfoSource to be generated,
the key field 0MATERIAL is transferred. The prerequisite for this is
that the basis InfoSource or basis InfoObject that you entered exists in
the BW system and that it is linked with a basis DataSource from the
OLTP system. This basis DataSource has to correspond with the current
classification or configuration DataSource via key fields of the same
name. If these prerequisites are not fulfilled, the system generates a
proposal for the key fields of the extraction structure. The key fields
proposed by the system can be overwritten later, as needed.
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
The basic InfoSource or basic InfoObject &V1& that you specified is
linked with a basic DataSource from the OLTP system that does not
correspond with the current DataSource &V2& from the source system. For
this reasons, the program cannot transfer key fields from the structure
of the basic InfoSource. Please check your entries and enter the correct
basic InfoSource, as needed. You can also ignore the message and
continue with the transaction. In this case, the system will generate
the proposals for the key fields that you can overwrite later as needed.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
CLBW_META020
- InfoObjeto Basis/Fuente &1 no relevante (consulte texto explicativo) ?Get instant SAP help. Start your 7-day free trial now.
CLBW_META019
El campo InfoObjeto Basis/Fuente está vacío (consulte texto explicativo)
¿Qué causa este problema? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the basic InfoSo...
CLBW_META018
InfoObjeto/Fuente & no tiene estruc.transf.(consulte texto explicativo)
¿Qué causa este problema? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the basic InfoSo...
CLBW_META021
InfoObjeto &1 no existe (consulte texto explicativo)
¿Qué causa este problema? For this reason, mapping cannot take place between the key field &V2& of the DataSource &V3& and the sel...
CLBW_META022
InfoObjeto Fuente &1 no es relevante (consulte texto explicativo)
¿Qué causa este problema? An InfoSource in the BW system that is supplied with master data from an OLTP DataSource has a link between an InfoObject...
Haga clic en este enlace para buscar todos los mensajes de SAP.