Do you have any question about this error?
Message type: E = Error
Message class: CLBW_META - For Generating Metadata
Message number: 018
Message text: InfoObjeto/Fuente & no tiene estruc.transf.(consulte texto explicativo)
When creating an InfoSource for classification or configuration data in
the BW system, the key fields of the basic InfoSource that are linked to
key fields of a OLTP basic DataSource are transferred into the
extraction structure. This only occurs if the key fields of this OLTP
basic DataSource have the same names as the key fields of the
classification DataSource. Klassifizierung-DataSource sind.
For example: a classification DataSource in the OLTP system 1CL_OMAT001
has the same key field as its corresponding basic DataSource (MATNR).
This base DataSource is linked to a basic InfoSource from the BW system
via the key field assignment, for example, MATNR <-> 0MATERIAL. In the
extraction structure of the classification InfoSource to be generated,
the key field 0MATERIAL is transferred. The prerequisite for this is
that the basis InfoSource or basis InfoObject that you entered exists in
the BW system and that it is linked with a basis DataSource from the
OLTP system. This basic DataSource has to correspond with the current
classification or configuration DataSource via key fields of the same
name. If these prerequisites are not fulfilled, the system generates a
proposal for the key fields of the extraction structure. The key fields
proposed by the system can be overwritten later, as needed.
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
The basic InfoSource &V1& you specified does not have a link (transfer
structure) to a basic DataSource from the OLTP system. For this reasons,
the program cannot transfer key fields from the structure of the basic
InfoSource. Check your entries and enter the correct basic InfoSource as
needed. You
can also ignore the message and continue with the transaction. In this
case, the system generates the proposals for the key fields, which you
can overwrite later as needed.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
CLBW_META018
- InfoObjeto/Fuente & no tiene estruc.transf.(consulte texto explicativo) ?Get instant SAP help. Start your 7-day free trial now.
CLBW_META017
Cantidad máxima de atributos excedida (consulte texto explicativo)
¿Qué causa este problema? You want to extend an InfoSource. This will then have more than 255 attributes.Respuesta del sistema There is not enough...
CLBW_META016
Fuente de datos ya está asignada
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
CLBW_META019
El campo InfoObjeto Basis/Fuente está vacío (consulte texto explicativo)
¿Qué causa este problema? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the basic InfoSo...
CLBW_META020
InfoObjeto Basis/Fuente &1 no relevante (consulte texto explicativo)
¿Qué causa este problema? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the basic InfoSo...
Haga clic en este enlace para buscar todos los mensajes de SAP.