Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: VSCAN - Virus Scan Interface
Message number: 108
Message text: Scanner group &1 is a BAdI implementation (scanner class: &2)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
VSCAN108
- Scanner group &1 is a BAdI implementation (scanner class: &2) ?The SAP error message VSCAN108 indicates that there is an issue related to the scanner group in the context of the SAP Virus Scan Interface (VSI). This error typically arises when the system is trying to use a scanner group that is defined as a BAdI (Business Add-In) implementation, which is not supported in the current context.
Cause:
- BAdI Implementation: The scanner group specified is linked to a BAdI implementation, which means it is not a standard scanner group that can be used directly for virus scanning.
- Configuration Issue: There may be a misconfiguration in the virus scan settings or the scanner group setup in the SAP system.
- Missing or Incorrect Scanner Class: The scanner class associated with the scanner group may not be correctly defined or may not exist.
Solution:
Check Scanner Group Configuration:
- Go to the transaction code
VSCN
(Virus Scan Configuration) and verify the configuration of the scanner groups.- Ensure that the scanner group you are trying to use is correctly defined and is not set as a BAdI implementation.
Use Standard Scanner Groups:
- If you are using a custom scanner group that is implemented as a BAdI, consider switching to a standard scanner group that is supported by the SAP system.
Review BAdI Implementation:
- If you need to use a BAdI implementation, ensure that it is correctly implemented and that it adheres to the expected interface for scanner groups.
Check for Updates:
- Ensure that your SAP system is up to date with the latest patches and updates, as there may be fixes related to the Virus Scan Interface.
Consult Documentation:
- Review the SAP documentation related to the Virus Scan Interface and BAdI implementations to ensure that you are following the correct procedures.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
Transaction Codes:
VSCN
: Virus Scan ConfigurationSE18
: BAdI ImplementationSE19
: BAdI Implementation BrowserSAP Notes: Check for any relevant SAP Notes that may address this specific error or provide additional guidance.
Documentation: Review the SAP Help Portal for detailed information on configuring the Virus Scan Interface and understanding BAdI implementations.
By following these steps, you should be able to identify the cause of the VSCAN108 error and implement a suitable solution.
Get instant SAP help. Sign up for our Free Essentials Plan.
VSCAN107
Virus scan server &1 was selected from scanner group &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
VSCAN106
Profile &1 failed, since step &2 failed (AND linkage)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
VSCAN109
Virus scan adapter &1 was selected from scanner group &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
VSCAN_CE001
Unable to lock '&1' (rc = &2).
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.