Message type: E = Error
Message class: UMK - Measures
Message number: 224
Message text: The benchmark InfoCube is not available; see help text
No benchmark data could be displayed because the benchmark InfoCube is
not available.
There are three possible causes for this problem:
The default BW system '&V1&' cannot be accessed. The system is possibly
not active at the present time.
The benchmark InfoCube '&V2&' does not exist in the default BW system.
However, the benchmark data is stored in InfoCube '&V2&' by default.
The benchmark InfoCube '&V2&' exists in the default BW system, but it
is not activated.
No benchmark data can be displayed.
Check whether the default BW system '&V1&' is correctly specified in
the transaction <DS:TRAN.UMC_DFTRFC>UMC_DFTRFC</>.
Check whether the default BW system can be accessed using transaction
<DS:TRAN.SM59>SM59</>.
Check whether the benchmark InfoCube '&V2&' exists in the default BW
system, and whether it is activated. You can do this using transaction
'RSD1' in the default BW system. Note: The InfoCube is only available
as of BW Content Release 2.0B.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
UMK224
- The benchmark InfoCube is not available; see help text ?The SAP error message UMK224 indicates that the benchmark InfoCube is not available. This error typically arises in the context of SAP BW (Business Warehouse) or SAP BW/4HANA when trying to access or utilize a specific InfoCube that is expected to be present but is not available in the system.
Cause:
- InfoCube Not Activated: The InfoCube may not be activated in the system. This can happen if it was recently created or modified.
- Transport Issues: If the InfoCube was transported from another system, there may have been issues during the transport process, leading to it not being available in the target system.
- Authorization Issues: The user may not have the necessary authorizations to access the InfoCube.
- Data Model Changes: Changes in the data model or InfoProvider structure may have rendered the InfoCube unavailable.
- Technical Issues: There could be underlying technical issues, such as database connectivity problems or system inconsistencies.
Solution:
- Check Activation: Verify if the InfoCube is activated. You can do this by navigating to the InfoCube in the Data Warehousing Workbench (RSA1) and checking its status.
- Re-activate the InfoCube: If it is not activated, activate it again. This can often resolve the issue.
- Check Transport Logs: If the InfoCube was recently transported, check the transport logs for any errors or warnings that might indicate why it is not available.
- Review Authorizations: Ensure that the user has the necessary authorizations to access the InfoCube. This can be checked in the user roles and authorizations.
- Check Data Model: Review any recent changes to the data model that might affect the InfoCube. Ensure that all dependencies are intact.
- System Check: Perform a system check to ensure there are no underlying technical issues. This may involve checking database connections and system logs for errors.
Related Information:
If the problem persists after trying the above solutions, it may be necessary to involve your SAP Basis or BW support team for further investigation.
Get instant SAP help. Sign up for our Free Essentials Plan.
UMK223
Error while reading industry from default BW system '&'
What causes this issue? Measure Builder cannot read the industries from default BW system '&V1& ' There are two possible causes: Th...
UMK222
Error while reading the measure unit from default BW system '&'
What causes this issue? Measure Builder cannot read units from the default BW system '&V1&' There are two possible causes: The defa...
UMK225
Generation of read program for benchmark InfoCube data failed
What causes this issue? To write benchmark values into an InfoCube, and to read them from an InfoCube, a program is generated automatically at runtim...
UMK226
Error while reading benchmark InfoCube data from default BW system '&'
What causes this issue? When calling the BW function module &V3& an error occurs. The error message from the BW is the following: &V2&...
Click on this link to search all SAP messages.