Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: SPXN - Proxy Generation
Message number: 187
Message text: RFC consumer operation incompatible: response parameter &1 not found
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
SPXN187
- RFC consumer operation incompatible: response parameter &1 not found ?The SAP error message SPXN187 indicates that there is an issue with the Remote Function Call (RFC) where the response parameter expected by the consumer is not found. This typically occurs when there is a mismatch between the expected structure of the RFC interface and the actual structure being returned by the RFC provider.
Cause:
Mismatch in RFC Interface: The most common cause is that the RFC consumer is expecting a certain response structure (parameters) that the RFC provider is not returning. This can happen if:
- The RFC function module has been changed (parameters added, removed, or renamed) but the consumer has not been updated accordingly.
- The consumer is calling an outdated version of the RFC function module.
Incorrect Mapping: If the parameters are not correctly mapped in the consumer's code, it may lead to this error.
Versioning Issues: If there are multiple versions of the RFC function module, the consumer might be calling an older version that does not have the expected parameters.
Solution:
Check RFC Function Module: Verify the definition of the RFC function module on the provider side. Ensure that the expected response parameters are correctly defined and that they match what the consumer is expecting.
Update Consumer Code: If the RFC function module has been modified, update the consumer code to align with the new structure. This may involve:
- Updating the parameter names.
- Adding or removing parameters as necessary.
Test the RFC Call: Use transaction
SE37
orSE80
to test the RFC function module directly. This can help confirm that the function module is returning the expected parameters.Check for Version Conflicts: Ensure that the consumer is calling the correct version of the RFC function module. If there are multiple versions, make sure the consumer is updated to call the latest version.
Debugging: If the issue persists, consider debugging the RFC call to trace the parameters being sent and received. This can help identify where the mismatch is occurring.
Related Information:
SE37
to view and test function modules, and SE80
for more comprehensive development work.By following these steps, you should be able to identify and resolve the SPXN187 error effectively.
Get instant SAP help. Sign up for our Free Essentials Plan.
SPXN186
RFC consumer operation incompatible: request parameter &1 not found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN185
RFC consumer operation incompatible: defined parameter &1 not found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN188
A mapping mode has to be assigned
What causes this issue? See <DS:DE.PRX_HDR_MODE> Mapping Mode</>System Response The system issues an error message and will not allow y...
SPXN189
No implementation assigned for RFC operation &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.