Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: SPXN - Proxy Generation
Message number: 185
Message text: RFC consumer operation incompatible: defined parameter &1 not found
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
SPXN185
- RFC consumer operation incompatible: defined parameter &1 not found ?The SAP error message SPXN185 indicates that there is an issue with an RFC (Remote Function Call) consumer operation where a defined parameter is not found. This typically occurs when there is a mismatch between the parameters expected by the RFC function module and those being passed by the calling program or system.
Cause:
Parameter Mismatch: The most common cause is that the calling program is trying to pass a parameter that is not defined in the RFC function module. This could be due to:
- A typo in the parameter name.
- The parameter being removed or renamed in the RFC function module.
- The calling program being outdated and not reflecting the latest changes in the RFC function module.
Versioning Issues: If the RFC function module has been updated (e.g., parameters added, removed, or changed), and the consumer has not been updated accordingly, this error can occur.
Incorrect Function Module: The calling program might be invoking the wrong function module or an incorrect version of the function module.
Solution:
Check Parameter Names: Verify that the parameter names being passed in the calling program match exactly with those defined in the RFC function module. Pay attention to case sensitivity and spelling.
Update the Calling Program: If the RFC function module has been modified, update the calling program to ensure it aligns with the current definition of the RFC function module.
Check Function Module Version: Ensure that the correct version of the function module is being called. If there are multiple versions, make sure the consumer is using the intended one.
Regenerate RFC Metadata: If you are using a tool that generates code based on RFC metadata (like SAP PI/PO or other middleware), regenerate the metadata to ensure it reflects the latest changes.
Debugging: Use transaction
SE37
to check the function module definition and see the expected parameters. You can also use transactionSE80
to analyze the calling program and see how it interacts with the RFC.Consult Documentation: If available, refer to the documentation for the RFC function module to understand the expected parameters and their types.
Related Information:
Transaction Codes:
SE37
: Function Module MaintenanceSE80
: Object NavigatorSM59
: RFC Destinations (to check the configuration of the RFC connection)SAP Notes: Check SAP Notes for any known issues or updates related to the specific RFC function module you are using.
Testing: You can test the RFC function module directly in SE37
to ensure it works as expected without the calling program.
By following these steps, you should be able to identify and resolve the issue causing the SPXN185 error message.
Get instant SAP help. Sign up for our Free Essentials Plan.
SPXN184
RFC consumer operation incompatible: sync / async flag does not match
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN183
RFC consumer operation incompatible: used function modules do not match
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN186
RFC consumer operation incompatible: request parameter &1 not found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SPXN187
RFC consumer operation incompatible: response parameter &1 not found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.