Message type: E = Error
Message class: /SCWM/QINSP -
Message number: 233
Message text: Manuf. order &1: Presampling process not active at IOT level (whse &2)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/QINSP233
- Manuf. order &1: Presampling process not active at IOT level (whse &2) ?The SAP error message /SCWM/QINSP233 indicates that there is an issue related to the presampling process for a manufacturing order in the context of the Extended Warehouse Management (EWM) module. Specifically, the error states that the presampling process is not active at the Inspection Object Type (IOT) level for the specified warehouse.
Cause: Presampling Not Configured: The presampling process may not be activated for the specific Inspection Object Type (IOT) in the warehouse settings. Warehouse Configuration: The warehouse configuration may not include the necessary settings to allow presampling for the manufacturing order. IOT Settings: The specific IOT used for the manufacturing order may not have the presampling process enabled.
Solution: Check IOT Configuration: Go to the configuration settings for the Inspection Object Types in EWM. Ensure that the presampling process is activated for the relevant IOT. Activate Presampling: If presampling is not active, you may need to activate it in the configuration. This can typically be done in the Customizing
Get instant SAP help. Sign up for our Free Essentials Plan.
/SCWM/QINSP232
Prod: &1/Batch: &2: Inspection rule deactivated (IOT&3 insp. process)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/QINSP231
Mfg.Order &1: Assign. Project for Inspection Document &2 is changed to &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/QINSP234
Product &1/Batch &2: Insp. process deactivated by QIR (IOT &3 process)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/QINSP235
Insp. type &1 not relevant for insp. rule creation (no entry in Cust.)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.