Do you have any question about this error?
Message type: E = Error
Message class: /SCWM/DLV_SERIAL -
Message number: 316
Message text: Split after batch split is only allowed for HUs for SN req. &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SCWM/DLV_SERIAL316
- Split after batch split is only allowed for HUs for SN req. &1 ?The SAP error message
/SCWM/DLV_SERIAL316
indicates that there is an issue related to handling units (HUs) and batch splits in the context of serial number requirements in the Extended Warehouse Management (EWM) module. Specifically, the error states that a split after a batch split is only allowed for handling units that have serial number requirements.Cause:
This error typically occurs in the following scenarios:
Batch Split: You are trying to perform a split operation on a handling unit (HU) that has already undergone a batch split, but the handling unit does not meet the criteria for serial number requirements.
Serial Number Management: The handling unit may not be configured to manage serial numbers, or the serial number management settings are not correctly applied to the handling unit.
Configuration Issues: There may be configuration issues in the warehouse management settings that prevent the split operation from being executed as intended.
Solution:
To resolve this error, consider the following steps:
Check Handling Unit Configuration:
- Ensure that the handling unit (HU) is configured to manage serial numbers. You can do this by checking the material master data and the handling unit type settings.
Review Batch Management Settings:
- Verify that the batch management settings for the material are correctly configured. Ensure that the material is set up to allow for batch splits and that the relevant batch management settings are active.
Serial Number Assignment:
- If the handling unit is supposed to have serial numbers, ensure that the serial numbers are correctly assigned to the handling unit before attempting to perform the split.
Use Correct HU Types:
- Make sure you are using the correct handling unit types that support the operations you are trying to perform. Some HU types may have restrictions on splitting after a batch split.
Consult Documentation:
- Review SAP documentation or help notes related to handling units, batch management, and serial number management for additional insights and best practices.
Testing:
- If possible, test the split operation in a development or quality assurance environment to ensure that the changes made resolve the issue without causing other problems.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide specific notes or patches that address the issue.
Related Information:
/SCWM/HU
for handling unit management and /SCWM/BATCH
for batch management.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/SCWM/DLV_SERIAL315
Serial number &1 set by external system; change not allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/DLV_SERIAL314
Serial number &1 has been entered more than once
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/DLV_SERIAL317
Reassign serial numbers after outbound delivery split
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SCWM/DLV_SERIAL318
Unique item identifier &1 has been entered more than once
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.