Do you have any question about this error?
Message type: E = Error
Message class: SCTS_AIM - Messages for the AIM meta data repository
Message number: 056
Message text: Table lock modes changed to "completely locked" for this AIM/API.
During a ZDM upgrade, some database tables can be accessed by both the
productive application and the after-import methods (AIM) in parallel.
For these tables, it must be ensured that the productive application
does not write data into the key areas accessed (read or write access)
by the after import method. To ensure this, the AIM author declares in
which way these key ranges are blocked in the productive application.
The most important options are the lock modes "P " = "Write access to
the relevant key ranges is blocked" and "X" = " Write access to the
complete table is blocked".
In cases where the key ranges accessed by the AIM are blocked by special
locking mechanisms (such as lock mode = "P") in the application code
(which exist from a particular application release and support package
level (R/SPL)), it may happen that the source release of the current
upgrade is lower than R/SPL. In this case, the particular locking
mechanisms are not in place. This can cause data inconsistencies after
the upgrade.
To avoid these inconsistencies, the upgrade tool sets these tables as
read-only for the productive application on database level. For example,
the upgrade tool changes the classification provided by the AIM author
from "P" to "X".
For the AIM inspected here, the upgrade tool has re-classified the
tables with lock mode "P" to lock mode "X".
The upgrade tool informs you about this fact by writing this message to
the upgrade log.
No action required.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
SCTS_AIM056
- Table lock modes changed to "completely locked" for this AIM/API. ?The SAP error message SCTS_AIM056 indicates that a table lock mode has changed to "completely locked" for a specific Application Interface Framework (AIM) or Application Programming Interface (API). This typically occurs when there are issues with data consistency or when a process is trying to access a table that is currently locked by another transaction.
Cause:
- Concurrent Access: Multiple processes or transactions are trying to access the same table simultaneously, leading to a lock conflict.
- Long-Running Transactions: A transaction that takes a long time to complete can hold locks longer than expected, causing other transactions to wait or fail.
- Deadlocks: Situations where two or more transactions are waiting for each other to release locks, leading to a complete lock situation.
- Configuration Issues: Incorrect configuration of the AIM/API or the underlying database can lead to unexpected locking behavior.
Solution:
Identify Locking Transactions:
- Use transaction codes like
SM12
(to view and manage locks) andSM21
(to check system logs) to identify which transactions are holding locks on the table.- Analyze the lock entries to determine the source of the lock.
Terminate Long-Running Transactions:
- If a transaction is holding a lock for too long, consider terminating it using
SM12
orSM50
(to monitor and manage work processes).Optimize Transactions:
- Review and optimize the code of the transactions that are causing locks. Ensure that they are efficient and do not hold locks longer than necessary.
Increase Lock Timeout:
- If appropriate, consider increasing the lock timeout settings in the system configuration to allow transactions more time to complete before being forced to fail.
Review Configuration:
- Check the configuration of the AIM/API to ensure it is set up correctly and that there are no issues that could lead to locking problems.
Database Maintenance:
- Perform regular database maintenance to ensure that the database is healthy and that there are no underlying issues causing locking problems.
Related Information:
If the issue persists after trying the above solutions, it may be necessary to engage SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
SCTS_AIM055
XPRA &1 not enabled for the current start release.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCTS_AIM054
Could not create SLAPI instance for XPRA &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCTS_AIM057
SL_API &1 not enabled for the current start release.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCTS_AIM058
No lock modes adjustment P -> X needed. No tables with lock mode P found.
What causes this issue? During a ZDM upgrade, some database tables can be accessed by both the productive application and the after-import methods (A...
Click on this link to search all SAP messages.