Message type: E = Error
Message class: SCM_MD_R3_PI - SCM Master Data in Plug-In
Message number: 010
Message text: Unit &2 is not a valid unit of measure for the material
The serial number profile &V1& has an assigned unit of measure &V2&.
However, this unit of measure has not been maintained as the valid unit
for the material.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
SCM_MD_R3_PI010
- Unit &2 is not a valid unit of measure for the material ?The SAP error message SCM_MD_R3_PI010 indicates that the unit of measure (UoM) specified for a material is not valid. This error typically occurs in the context of SAP Supply Chain Management (SCM) or when working with materials in the SAP system.
Cause: Invalid Unit of Measure: The unit of measure you are trying to use for the material is not defined in the system or is not assigned to the material master.
Configuration Issues: The unit of measure may not be properly configured in the material master data or in the relevant UoM tables. Data Entry Errors: There may be a typographical error in the unit of measure being entered. Material Type Restrictions: Certain material types may have restrictions on which units of measure can be used.
Solution: Check Material Master Data: Go to the material master record (transaction code MM03). Verify that the unit of measure you are trying to use is listed in the "Units of Measure"
Get instant SAP help. Sign up for our Free Essentials Plan.
SCM_MD_R3_PI001
The warehouse number of the decentralized SCM system must be unique
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCMP_EXCP017
Object &1 (type &2) is in the exclusion list and is not compared
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SCM_MD_R3_PI011
Unit &1 does not correspond to base unit of measure of material
What causes this issue? A serial number profile has been assigned to the material. In the definition of the serial number profile (table TSERIAL), a ...
SCM_MD_R3_PI020
Change in parallel unit of measure no (longer) possible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.