Message type: E = Error
Message class: /SAPCND/GENERATOR -
Message number: 341
Message text: Ext. scale elelment TTYP &1 could not be written into the DDIC
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/SAPCND/GENERATOR341
- Ext. scale elelment TTYP &1 could not be written into the DDIC ?The SAP error message /SAPCND/GENERATOR341 indicates that there is an issue with writing an external scale element (TTYP) into the Data Dictionary (DDIC). This error typically arises in the context of the SAP Condition Management or similar modules where external scale elements are used.
Cause: Missing Authorization: The user executing the operation may not have the necessary authorizations to write to the DDIC. Inconsistent Data: There may be inconsistencies or errors in the data being processed, which prevent the successful writing of the scale element. Technical Issues: There could be technical issues such as database locks, transport issues, or problems with the underlying database.
Configuration Issues: The configuration of the external scale element may not be correct, leading to issues when trying to write it to the DDIC.
Solution: Check Authorizations: Ensure that the user has the necessary authorizations to perform the operation. This may involve checking roles and permissions in the SAP system. Review Data: Validate the
Get instant SAP help. Sign up for our Free Essentials Plan.
/SAPCND/GENERATOR340
Generation of external scale element TTYP &1 was started
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SAPCND/GENERATOR339
Generate table type for internal scale element &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SAPCND/GENERATOR342
Ext. scale element TTYP &1 was written into the DDIC successfully
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/SAPCND/GENERATOR343
Activation of external scale element TTYP &1 failed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.