Do you have any question about this error?
Message type: E = Error
Message class: RSM1 - Messages for AWB, Scheduler and Monitor (new)
Message number: 113
Message text: Cannot update DataSource &1 to a DataStore object
You want to update DataSource &V1& with delta process &V2& in update
mode &V3& to an DataStore object.
Update mode 'Construct Opening Status' is usually not permitted for
updating a DataStore object. With the update modes 'Initialization of
the Delta Process', and 'Delta Update', whether an update to a DataStore
object update is permitted depends on the delta process,.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Choose the <LS>full update</> update mode or deactivate all DataStore
objects as targets for the update.
Error message extract from SAP system. Copyright SAP SE.
RSM1113
- Cannot update DataSource &1 to a DataStore object ?The SAP error message RSM1113, which states "Cannot update DataSource &1 to a DataStore object," typically occurs in the context of data extraction and loading processes in SAP BW (Business Warehouse). This error indicates that there is an issue with updating a DataSource to a DataStore object (DSO).
Causes:
- DataSource Configuration Issues: The DataSource may not be properly configured or may not be compatible with the target DataStore object.
- Data Transfer Issues: There may be issues with the data transfer process, such as incorrect mappings or transformations.
- Data Integrity Issues: The data being loaded may violate integrity constraints defined in the DataStore object.
- Authorization Issues: The user executing the data load may not have the necessary authorizations to perform the update.
- Technical Issues: There may be technical issues such as system performance problems, locks on the DataStore object, or other system-related errors.
Solutions:
- Check DataSource Configuration: Verify that the DataSource is correctly configured and that it is compatible with the DataStore object. Ensure that the fields in the DataSource match the fields in the DSO.
- Review Data Transfer Process: Check the data transfer process for any errors or warnings. Ensure that the mappings and transformations are correctly set up.
- Validate Data: Inspect the data being loaded for any inconsistencies or violations of integrity constraints. Clean or transform the data as necessary.
- Check Authorizations: Ensure that the user has the necessary authorizations to perform the data load. This may involve checking roles and permissions in the SAP system.
- Monitor System Performance: Check for any performance issues or locks on the DataStore object. You may need to resolve any locks or wait for system performance to improve.
- Review Logs: Look at the application logs (transaction SLG1) for more detailed error messages that can provide additional context for the issue.
Related Information:
By following these steps, you should be able to identify the root cause of the RSM1113 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RSM1112
DataSource &2 cannot be updated in an InfoCube
What causes this issue? DataSource &V2& uses delta process &V1&, which is not suitable for direct updates into an InfoCube because th...
RSM1111
Load not possible; choose transfer method PSA
What causes this issue? The DataSource needs to be serialized. To ensure that data is transferred in serialized form, you are only permitted to load ...
RSM1114
DataSource &2 requires serialization with delta mode &1 with up.mode &3
What causes this issue? The delta process &V1& for DataSource &V2& requires strict compliance of the time sequence of loaded records ...
RSM1115
First init. in DataStore object &1 is request &2
What causes this issue? Entry &V2& is the first entry in DataStore object &V1&. This entry is not, however, an active init. request.S...
Click on this link to search all SAP messages.