RSDD_ZA161
- Check of indexes with incorrect information in topology ?The SAP error message RSDD_ZA161, which indicates a check of indexes with incorrect information in topology, typically arises in the context of SAP BW (Business Warehouse) or SAP BW/4HANA environments. This error is related to the data modeling and indexing processes within the BW system.
Cause:
The error can occur due to several reasons, including:
- Inconsistent Metadata: There may be inconsistencies in the metadata of InfoProviders, such as InfoCubes or DataStore Objects (DSOs), which can lead to incorrect index information.
- Corrupted Indexes: Indexes may become corrupted due to system issues, improper data loads, or failed processes.
- Changes in Data Model: If there have been recent changes to the data model (e.g., changes in InfoObjects, InfoProviders, or transformations), the existing indexes may not reflect these changes correctly.
- Transport Issues: If objects were transported between systems (e.g., from development to production), there may be discrepancies in the index information.
Solution:
To resolve the RSDD_ZA161 error, you can follow these steps:
Check and Repair Indexes:
- Use transaction code
RSA1
to access the Data Warehousing Workbench.- Navigate to the InfoProvider that is causing the issue.
- Right-click on the InfoProvider and select "Manage" or "Repair" to rebuild the indexes.
Rebuild the Data Model:
- If the issue persists, consider reactivating the InfoProvider. This can be done by right-clicking on the InfoProvider and selecting "Activate" or "Rebuild".
- Ensure that all transformations and data flows are correctly defined and activated.
Check for Inconsistencies:
- Use transaction
RSD1
to check the InfoObjects and InfoProviders for inconsistencies.- Use the "Check" function to identify any issues in the data model.
Perform a Consistency Check:
- You can run the consistency check for the entire BW system using transaction
RS_CHECK
to identify any other potential issues.Transport Issues:
- If the issue is related to a transport, ensure that all related objects were transported correctly and that there are no missing dependencies.
Consult SAP Notes:
- Check the SAP Support Portal for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
Related Information:
RSA1
(Data Warehousing Workbench), RSD1
(InfoObject Maintenance), and RS_CHECK
(Consistency Check).By following these steps, you should be able to diagnose and resolve the RSDD_ZA161 error effectively. If the problem persists, consider reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
RSDD_ZA160
Test for checks that are deactivated because BWA is a single instance
What causes this issue? The system checks whether the connected SAP NetWeaver BW Accelerator is a single system instance. This means that the SAP Net...
RSDD_ZA159
Check of Hosts That Do Not Use Shared Memory
What causes this issue? Under certain circumstances, it is possible that the BWA is configured in such a way that it does not used shared memory. Thi...
RSDD_ZA162
Check for BWI indexes with inconsistent data
What causes this issue? This check looks for inconsistencies in the various indexes in SAP NetWeaver BW Accelerator. Inconsistencies can arise, for e...
RSDD_ZA163
Check for inactive backup server
What causes this issue? This check checks the backup server of the backup and recovery solution of the SAP NetWeaver BI Accelerator. If the backup se...
Click on this link to search all SAP messages.