Do you have any question about this error?
Message type: E = Error
Message class: RSDA - BW Archiving: Messages
Message number: 246
Message text: Archiving/reload request &1 not yet completed
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RSDA246
- Archiving/reload request &1 not yet completed ?The SAP error message RSDA246 indicates that an archiving or reload request has not yet been completed. This error typically occurs in the context of data archiving and data management processes within SAP BW (Business Warehouse) or SAP HANA environments.
Cause:
The error message RSDA246 can be caused by several factors, including:
- Incomplete Archiving Process: The archiving or reload request has not finished processing. This could be due to a long-running job or a job that has failed.
- Job Scheduling Issues: The job responsible for completing the archiving or reload request may not have been scheduled or executed properly.
- Database Locks: There may be locks on the database that prevent the completion of the archiving process.
- System Performance Issues: High system load or performance issues can delay the completion of the archiving process.
- Configuration Issues: Incorrect configuration settings in the archiving process can lead to incomplete requests.
Solution:
To resolve the RSDA246 error, you can take the following steps:
Check Job Status:
- Go to transaction code SM37 to check the status of the job related to the archiving or reload request. Look for any jobs that are still running or have failed.
- If the job is still running, you may need to wait for it to complete. If it has failed, review the job log for errors.
Review Logs:
- Check the application logs (transaction code SLG1) for any relevant error messages that could provide more context about why the archiving process did not complete.
Database Locks:
- Use transaction code SM12 to check for any database locks that might be preventing the completion of the archiving process. If you find locks that are no longer needed, you can release them.
Re-run the Archiving Process:
- If the job has failed, you may need to re-run the archiving or reload request. Ensure that all prerequisites are met before doing so.
System Performance:
- Monitor system performance and resource usage. If the system is under heavy load, consider scheduling the archiving process during off-peak hours.
Configuration Review:
- Review the configuration settings for the archiving process to ensure they are correct. This may involve checking settings in the Data Warehousing Workbench or related configuration areas.
Consult Documentation:
- Refer to SAP documentation or notes related to archiving and data management for any specific guidance or known issues.
Related Information:
By following these steps, you should be able to identify the cause of the RSDA246 error and take appropriate action to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RSDA245
No restrictions were defined
What causes this issue? The current variant for data archiving process &v1& does not (yet) have any restrictions.System Response The InfoPro...
RSDA244
No requests of type '&2' that can be continued found for DAP '&1'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDA247
Data area to be archived is empty
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDA248
Inconsistency with archiving pointers in request status management
What causes this issue? In the request status management of the InfoProvider &v1&, the request with the SID &v2& is entered as the la...
Click on this link to search all SAP messages.