Message type: E = Error
Message class: RSCRT - Near-To-Real-Time Messages
Message number: 347
Message text: Daemon &2 may not be assigned to DataSource &1
You tried to assign DataSource &V1& to the daemon &V2&. This DataSource
is assigned to a data transfer process (DTP) that defines the parameters
for the InfoProvider &V3&. A DTP that supplies data to the InfoProvider
is also assigned to a second DataSource. Daemon &V4& is assigned to this
second DataSource.
However, all the DTPs that supply data to the InfoProvider &V3& and thus
to the DataSources that are sources for these DTPs must be assigned to
the same daemon.
You cannot assign the daemon &V2& to the DataSource &V1&.
Decide on one of the two daemons, which should then execute both DTPs
that supply data to the InfoProvider &V3&.
If you decide on daemon &V4&, assign this daemon to DataSource &V1&.
If you decide on a different daemon, first delete the assignment of
daemon &V4& to all the Data Sources to which a DTP that supplies data to
InfoProvider &V3& is assigned. Then make the assignments to the other
daemon.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message RSCRT347 indicates that a specific daemon (a background process) is not assigned to a particular DataSource. This error typically occurs in the context of SAP BW (Business Warehouse) or SAP BW/4HANA when there are issues with the configuration of data extraction processes.
Cause: The error can arise due to several reasons: Daemon Not Assigned: The specified daemon (background process) is not assigned to the DataSource in the system configuration.
Configuration Issues: There may be misconfigurations in the settings of the DataSource or the associated extraction process. Transport Issues: If the DataSource was transported from another system, the daemon assignment may not have been included in the transport. System Updates: Changes or updates in the system may have led to the loss of the assignment.
Solution: To resolve the RSCRT347 error, you can follow these steps: Check Daemon Assignment: Go to the DataSource configuration in the SAP BW system. Verify if the correct daemon is assigned to the
Get instant SAP help. Sign up for our Free Essentials Plan.
RSCRT346 First create an RDA InfoPackage for DataSource &1(&2)
What causes this issue? There is no InfoPackage for real-time data acquisition (RDA) for the DataSource &V1& (&V2&).System Response ...
RSCRT345 There is no active PUSH InfoPackage for DataSource &1(&2)
What causes this issue? There is no active push InfoPackage for the DataSource &V1& (source system &V2&).System Response You cannot ...
RSCRT348 Cannot assign daemon &2 to data transfer process &1
What causes this issue? You are trying to assign data transfer process (DTP) &V1& to DataSource &V3&. DataSource &V3& is assi...
RSCRT350 &1 error occurred while executing InfoPackage &2 with daemon &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.