Do you have any question about this error?
Message type: E = Error
Message class: RSAR - Data Transfer and Metadata Maintenance
Message number: 395
Message text: The compounded InfoObject &2 is missing for InfoObject &1
The InfoObject &V1& is compounded with the InfoObject &V2&. However,
InfoObject &V2& is not in the transfer structure.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Add InfoObject &V2& to the transfer structure and maintain mapping as
required.
Error message extract from SAP system. Copyright SAP SE.
RSAR395
- The compounded InfoObject &2 is missing for InfoObject &1 ?The SAP error message RSAR395 indicates that there is a problem with the compounded InfoObject in your SAP BW (Business Warehouse) system. Specifically, it means that the compounded InfoObject (the one that combines multiple characteristics) is missing for the specified InfoObject.
Cause:
- Missing Compounded InfoObject: The compounded InfoObject that is supposed to be associated with the specified InfoObject does not exist in the system.
- Incorrect Configuration: There may be an issue with the configuration of the InfoObjects, such as incorrect settings or missing dependencies.
- Transport Issues: If the InfoObjects were transported from one system to another (e.g., from development to production), the compounded InfoObject may not have been included in the transport request.
- Deletion: The compounded InfoObject may have been deleted or not activated properly.
Solution:
- Check InfoObject Definitions: Go to the InfoObject maintenance transaction (e.g., RSA1) and verify that the compounded InfoObject exists and is correctly defined.
- Recreate Compounded InfoObject: If the compounded InfoObject is missing, you may need to recreate it. Ensure that it is properly defined and activated.
- Transport Check: If the issue arose after a transport, check the transport logs to ensure that all necessary objects were included in the transport request.
- Activation: If the compounded InfoObject exists but is not activated, activate it in the InfoObject maintenance.
- Check Dependencies: Ensure that all dependent InfoObjects are also active and correctly configured.
- Consult Documentation: Review SAP documentation or notes related to InfoObjects and compounded InfoObjects for any specific guidance or known issues.
Related Information:
By following these steps, you should be able to identify and resolve the issue related to the RSAR395 error message in your SAP BW system.
Get instant SAP help. Start your 7-day free trial now.
RSAR394
Select at least one InfoObject in the selection column
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSAR393
Formulas have been activated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSAR396
Cannot generate PSAs with more than 1000 characters
What causes this issue? The PSA for which you want to generate an export DataSource is larger than 1000 bytes. This causes errors when you activate t...
RSAR397
UD Connect connection data is not correct
What causes this issue? BI Java connector '&V2&' is entered for source system &V1&. This is not correct.System Response Th...
Click on this link to search all SAP messages.