How To Fix RMSA450QM019 - Inspections are referenced although "NO_REFERNC" parameter is set


RMSA450QM019 - Overview

  • Message type: E = Error

  • Message class: RMSA450QM - RMS: ATL QM Message Texts for QM Title Element

  • Message number: 019

  • Message text: Inspections are referenced although "NO_REFERNC" parameter is set

  • Show details Hide details
  • What causes this issue?

    You have chosen the
    NO_REFERNC - <ZK>Sets and Locks "Cancel Reference" Indic
    (Inspection Chars)</> parameter
    in Customizing for <ZK>Recipe Management</> in the
    IMG activity <DS:SIMG.RMS_QM_10>Specify Environment Parameters</>.
    This means that the <ZK>Cancel Reference</> field is locked against data
    entry, but is always displayed on a value basis. As a result, the
    reference to master inspection characteristics is always canceled so
    that some inspection characteristic attributes (for example, tolerance
    limits) are ready for input.
    This setting is also expected for the recipe data that is read from the
    database.

    System Response

    How to fix this error?

    If you want the data to remain unchanged, cancel the action. Otherwise,
    the system converts the data accordingly.

    Procedure for System Administrators

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.


    Error message extract from SAP system. Copyright SAP SE.


RMSA450QM019 - Details

  • The SAP error message RMSA450QM019 indicates that inspections are being referenced in a situation where the system is configured with the "NO_REFERNC" parameter set. This typically occurs in the context of Quality Management (QM) processes within SAP, particularly when dealing with inspection lots or quality inspections.
    
    Cause: The error arises when the system is trying to process an inspection lot or a quality inspection, but the configuration parameter "NO_REFERNC" is set to prevent referencing inspections. This can happen due to: Configuration Settings: The "NO_REFERNC" parameter is likely set in the system configuration, which indicates that inspections should not be referenced in certain processes. Process Flow: The process being executed is attempting to reference inspections that are not allowed due to the current configuration. Data Integrity Issues: There may be inconsistencies in the data or process flow that lead to the system attempting to reference inspections incorrectly.
    Solution: To resolve this error, you can consider the following steps: Check

    Already have an account? Login here!