Message type: E = Error
Message class: R7 - BW: Data basis
Message number: 008
Message text: InfoObject &1 not converted correctly
The master data table '/BIC/M&V1&' or '/BIC/M&V1&' has not been
converted into a view. The conversion program RSDG_XPRA_IOBJ_20A, which
automatically carries out the conversion from 1.2B to 2.0, probably ran
into errors.
The characteristic &V1& must be converted to 2.0 status.
Run the program RSDG_XPRA_IOBJ_20A in dialog version. See note no.
0323155 for a more detailed description of the error and procedure.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message R7008, which states "InfoObject &1 not converted correctly," typically occurs during the process of data extraction or transformation in SAP BW (Business Warehouse) or during the upgrade of InfoObjects. This error indicates that there is an issue with the conversion of a specific InfoObject, which can be due to various reasons. Causes: Data Type Mismatch: The data type of the InfoObject may not match the expected type in the target system. Inconsistent Data: There may be inconsistencies in the data stored in the InfoObject, such as invalid characters or formats. Missing or Incorrect Conversion Routines: If there are custom conversion routines associated with the InfoObject, they may not be functioning correctly. Upgrade Issues: If the error occurs during an upgrade, it may be due to changes in the structure or properties of the InfoObject that were not handled properly. Transport Issues: If the InfoObject was transported from one system to another, there
Get instant SAP help. Sign up for our Free Essentials Plan.
R7007 Cannot repair InfoObject &1 (SIDs already exist)
What causes this issue? InfoObject &V1& is inconsistent because of missing table entries and the system cannot repair it.System Response The...
R7006 InfoObject &1 is inconsistent; repair
What causes this issue? InfoObject &V1& is inconsistent. The program is terminated deliberately to avoid errors. A possible reason for the in...
R7009 Conversion block (master data) on characteristic &1 was deleted manually
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7010 Object namespace & is already used as a generation namespace
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.