Message type: E = Error
Message class: R7 - BW: Data basis
Message number: 007
Message text: Cannot repair InfoObject &1 (SIDs already exist)
InfoObject &V1& is inconsistent because of missing table entries and
the system cannot repair it.
The system dumps to prevent fatal errors.
Proceed as follows to repair the object:
Call up Transaction SE16 in the table RSDCHABASLOC and choose 'Generate
entries - F5'
In the field CHABASNM (reference characteristic), enter the name of the
reference characteristic of InfoObject &V1&.
In the field NUMBRANR 'Number of number ranges for the characteristic',
enter '0000000' (7 zeros).
Activate InfoObject &V1&.
Warning !! If you do not active the InfoObject, more inconsistencies
will follow !!
If errors occur after you activate it, contact SAP Support before using
the system again.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
R7007
- Cannot repair InfoObject &1 (SIDs already exist) ?The SAP error message R7007, "Cannot repair InfoObject &1 (SIDs already exist)," typically occurs during the repair of an InfoObject in the SAP BW (Business Warehouse) system. This error indicates that the system is unable to repair the InfoObject because the System IDs (SIDs) for that InfoObject already exist in the database.
Cause: Existing SIDs: The primary cause of this error is that the SIDs for the InfoObject you are trying to repair already exist in the SID table. This can happen if the InfoObject has been previously activated or if there are existing entries in the SID table that conflict with the repair process. Data Inconsistency: There may be inconsistencies in the data or metadata related to the InfoObject, which can prevent the repair process from completing successfully. Incorrect Repair Process: Attempting to repair an InfoObject that does not require repair or is already in a consistent state can also lead to this
Get instant SAP help. Sign up for our Free Essentials Plan.
R7006
InfoObject &1 is inconsistent; repair
What causes this issue? InfoObject &V1& is inconsistent. The program is terminated deliberately to avoid errors. A possible reason for the in...
R7005
InfoProvider &1 is inconsistent; reactivate
What causes this issue? The InfoProvider &V1& is inconsistent or has been set to 'inactive' because dependent InfoObjects have been...
R7008
InfoObject &1 not converted correctly
What causes this issue? The master data table '/BIC/M&V1&' or '/BIC/M&V1&' has not been converted into a view. T...
R7009
Conversion block (master data) on characteristic &1 was deleted manually
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.