Do you have any question about this error?
Message type: E = Error
Message class: QP - Message IDs for function module group QPAA
Message number: 874
Message text: Master insp. characteristic &1 &2 &3 does not have a valid use in plans
No valid use in a plan exists for master inspection characteristic &V1&
&V2& &V3&.
The master inspection characteristic cannot be displayed.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
QP874
- Master insp. characteristic &1 &2 &3 does not have a valid use in plans ?The SAP error message QP874 indicates that a master inspection characteristic (MIC) does not have a valid use in the inspection plans. This typically occurs when the inspection characteristic is not properly configured or is not assigned to the relevant inspection plan.
Cause:
- Invalid Configuration: The master inspection characteristic may not be correctly configured for the specific inspection plan.
- Missing Assignment: The MIC might not be assigned to the inspection plan or the characteristic is not relevant for the specific inspection lot.
- Status Issues: The MIC may be in a status that does not allow it to be used in inspection plans (e.g., it might be marked as inactive).
- Versioning Issues: If there are multiple versions of the inspection characteristic, the version being referenced may not be valid.
Solution:
Check Master Inspection Characteristic:
- Go to the transaction code
QMC1
(for creating MIC) orQMC2
(for changing MIC).- Verify that the MIC is correctly defined and active.
- Ensure that the characteristic is set up with the correct data type and measurement unit.
Review Inspection Plan:
- Use transaction code
QP01
(for creating inspection plans) orQP02
(for changing inspection plans).- Check if the MIC is included in the inspection plan and that it is relevant for the specific inspection lot.
- If the MIC is missing, add it to the inspection plan.
Check Status:
- Ensure that the MIC is not marked as inactive or in a status that prevents its use.
- If necessary, change the status of the MIC to active.
Version Control:
- If there are multiple versions of the MIC, ensure that the correct version is being referenced in the inspection plan.
Consult Documentation:
- Review SAP documentation or help files related to Quality Management (QM) for additional guidance on configuring MICs and inspection plans.
Testing:
- After making the necessary changes, test the inspection plan to ensure that the error message no longer appears.
Related Information:
QMC1
- Create Master Inspection CharacteristicQMC2
- Change Master Inspection CharacteristicQP01
- Create Inspection PlanQP02
- Change Inspection PlanIf the issue persists after following these steps, it may be beneficial to consult with your SAP support team or refer to SAP community forums for further assistance.
Get instant SAP help. Start your 7-day free trial now.
QP873
Dynamic modification rule & is not compatible with sampling procedure &
What causes this issue? The allowed relationship is not defined for the combination specified above.System Response The system issues an error messa...
QP872
You must enter a version for the new inspection method
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QP875
Master inspection characteristic is not used in any material spec.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QP876
There is no link between a master inspection char. and a class char.
What causes this issue? No class characteristic has been linked to the master inspection characteristic.System Response The system issues an error m...
Click on this link to search all SAP messages.