Do you have any question about this error?
Message type: E = Error
Message class: QIE_SETUP -
Message number: 055
Message text: Sample-drawing unit overridden by container type in sample-drawing proc.
You have specified a sample-drawing procedure of the type <LS>Container
</> and also a sample-drawing unit in the arguments for an inspection
rule.
For sample-drawing procedure of the type <LS>Container</>, the
sample-drawing unit is determined dynamically when the inspection is
executed or simulated, depending on the existing container unit.
The specified sample-drawing unit is overridden when the inspection is
executed or simulated.
Delete the sample-drawing unit from the arguments for the inspection
rule.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
QIE_SETUP055
- Sample-drawing unit overridden by container type in sample-drawing proc. ?The SAP error message QIE_SETUP055 indicates that there is an issue with the sample-drawing unit being overridden by the container type in the sample-drawing process. This typically occurs in the context of quality management and sampling procedures within SAP.
Cause:
The error usually arises due to a mismatch between the sample-drawing unit defined in the quality inspection plan and the container type being used. Specifically, it can happen when:
- The sample-drawing unit specified in the inspection plan does not match the container type that is being used for the inspection.
- The configuration settings for the sample-drawing procedure are not aligned with the container type settings.
- There may be inconsistencies in the master data related to the material or the inspection lot.
Solution:
To resolve the QIE_SETUP055 error, you can take the following steps:
Check Inspection Plan:
- Review the inspection plan associated with the material to ensure that the sample-drawing unit is correctly defined.
- Make sure that the sample-drawing unit is compatible with the container type being used.
Review Container Type Settings:
- Verify the settings for the container type in the system. Ensure that it is configured correctly to match the expected sample-drawing units.
- Check if the container type is set up to allow the sample-drawing unit that you are trying to use.
Adjust Sample-Drawing Procedure:
- If necessary, adjust the sample-drawing procedure to ensure that it aligns with the container type. This may involve changing the sample-drawing unit or modifying the procedure settings.
Master Data Consistency:
- Ensure that the master data for the material, including the quality management settings, is consistent and correctly configured.
- Check for any discrepancies in the material master or the quality info records.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on the sample-drawing process and container types.
Testing:
- After making the necessary adjustments, perform a test to ensure that the error no longer occurs and that the sample-drawing process works as intended.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a technical consultant who specializes in SAP QM processes.
Get instant SAP help. Start your 7-day free trial now.
QIE_SETUP054
Rule specified for sample determination not suitable for sample type &1
What causes this issue? You have specified a rule for sample determination. However, the rule you have specified conflicts with the specified sample ...
QIE_SETUP053
Arguments specified for sample type 3 are not suitable for sample type &1
What causes this issue? You have specified arguments that relate to the sample type <LS>Use Sampling Scheme</>, for example, a sampling s...
QIE_SETUP056
Sample-drawing procedure of type BAdI does not contain sample-draw. unit
What causes this issue? You have specified a sample-drawing procedure of the type <LS>Individual sample-drawing (BAdI)</> and also a samp...
QIE_SETUP057
No automatic release of samples despite external system being specified
What causes this issue? The inspection rule arguments contain details of an external quality management system and a sample-drawing procedure for whi...
Click on this link to search all SAP messages.