Message type: E = Error
Message class: QIE_SETUP -
Message number: 051
Message text: Arguments specified for sample type 1 are not suitable for sample type &1
You have specified arguments that relate to the sample type <LS>Fixed
Sample Size</>, for example, a fixed sample size, its unit of measure,
or a fixed acceptance number. These specifications conflict with the
sample type you have specified, namely &V1&.
When an inspection rule is created or inspection rule arguments are
changed, the arguments for the sample type <LS>Fixed Sample Size</> are
deleted by the system.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
QIE_SETUP051
- Arguments specified for sample type 1 are not suitable for sample type &1 ?The SAP error message QIE_SETUP051 indicates that there is a mismatch between the arguments specified for a sample type and the expected arguments for that sample type in the Quality Management (QM) module. This typically occurs when setting up sampling procedures or when defining characteristics for a specific sample type.
Cause: The error is usually caused by one of the following issues: Incorrect Sample Type Configuration: The sample type you are trying to use may not be configured correctly, or the arguments provided do not match the expected format or requirements for that sample type. Mismatch in Characteristics: The characteristics defined for the sample type may not align with the sample type's requirements, leading to this error. Data Entry Errors: There may be typographical errors or incorrect values entered in the configuration settings for the sample type.
Solution: To resolve the error, you can take the following steps: Check Sample Type Configuration: Go to the configuration settings for the
Get instant SAP help. Sign up for our Free Essentials Plan.
QIE_SETUP050
Insp. severity &1 from dyn.mod.rule &2 does not exist in samp. scheme &3
What causes this issue? The specified dynamic modification rule &V2& uses the inspection severity &V1&. No sampling plans for this in...
QIE_SETUP049
Sample args are not practical for inspection procedures "100% Inspection"
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QIE_SETUP052
Arguments specified for sample type 2 are not suitable for sample type &1
What causes this issue? You have specified arguments that relate to the sample type <LS>Percenta ge of Lot Size</>, for example, a sample...
QIE_SETUP053
Arguments specified for sample type 3 are not suitable for sample type &1
What causes this issue? You have specified arguments that relate to the sample type <LS>Use Sampling Scheme</>, for example, a sampling s...
Click on this link to search all SAP messages.