Message type: E = Error
Message class: QD - Message-Id. für Dynamisierung
Message number: 094
Message text: The inspection lot origin is not fully maintained in customizing
The inspection lot origin &V1& is not available as an entry in the
table of origins (view V_TQ33).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
QD094
- The inspection lot origin is not fully maintained in customizing ?The SAP error message QD094, which states "The inspection lot origin is not fully maintained in customizing," typically occurs when there is an issue with the configuration of the inspection lot origin in the Quality Management (QM) module. This error indicates that the system cannot find the necessary settings for the specified inspection lot origin, which is required for creating or processing inspection lots.
Cause: Missing Customizing Settings: The inspection lot origin may not be fully defined in the customizing settings. This can happen if the relevant configuration for the inspection lot origin is incomplete or missing. Incorrect Configuration: The settings for the inspection lot origin may be incorrectly configured, leading to inconsistencies in how the system processes inspection lots. Transport Issues: If the configuration was recently transported from another system, there may have been issues during the transport process that resulted in incomplete settings.
Solution: To resolve the QD094 error, follow these steps: Check Customizing Settings: Go
Get instant SAP help. Sign up for our Free Essentials Plan.
QD093
No entry in TQ39A for the dynamic modification level
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QD092
The sampling scheme &1 is incomplete
What causes this issue? A sampling procedure was assigned to a characteristic in the inspection plan that references sampling scheme &v1&. In...
QD095
The dynamic modification criteria are not fully maintained
What causes this issue? There is no entry in the view V_TQ39 for the dynamic modification criterion with the origin &V1&.System Response The...
QD096
Activation is not allowed, if there is no dynamic mod. level reference
What causes this issue? You can only carry out an activation, where a referenced dynamic modification level exists.System Response The system issues...
Click on this link to search all SAP messages.