Do you have any question about this error?
Message type: E = Error
Message class: PPEMPL -
Message number: 104
Message text: You do not have authorization to start the conversion report productively
You have attempted to start the PVS-MPL conversion report in productive
mode. However, you do not have authorization for this.
The system cancels the report.
If you want to execute the conversion, contact your system administrator
to get the authorization C_PPE_MPL.
If you only want to check whether a conversion is even possible, start
the report in test mode.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PPEMPL104
- You do not have authorization to start the conversion report productively ?The SAP error message PPEMPL104 indicates that a user does not have the necessary authorization to start a conversion report in a productive environment. This error typically arises in the context of SAP's Product Lifecycle Management (PLM) or similar modules where specific authorizations are required to execute certain transactions or reports.
Cause:
- Authorization Issues: The user attempting to run the conversion report lacks the required authorization objects or roles assigned to their user profile.
- Role Configuration: The roles assigned to the user may not include the necessary permissions for executing conversion reports in a productive environment.
- Environment Restrictions: The system may have restrictions in place that prevent certain users from executing reports in a productive environment, possibly for security or compliance reasons.
Solution:
- Check User Roles: Verify the roles assigned to the user in transaction
SU01
(User Maintenance). Ensure that the user has the appropriate roles that include the necessary authorizations for executing conversion reports.- Authorization Objects: Identify the specific authorization objects required for the conversion report. This can typically be done by checking the documentation for the report or consulting with your SAP security team.
- Request Additional Authorizations: If the user lacks the necessary authorizations, they should request additional permissions from the SAP security administrator or the person responsible for managing user roles in your organization.
- Testing in Development: If the user needs to test the report, they may be able to do so in a development or quality assurance environment where they have the necessary permissions.
- Consult SAP Documentation: Review SAP documentation or notes related to the specific report to understand any additional requirements or restrictions.
Related Information:
SU01
(User Maintenance), PFCG
(Role Maintenance), and SU53
(Authorization Check) to analyze authorization issues.By following these steps, you should be able to resolve the authorization issue related to the PPEMPL104 error message.
Get instant SAP help. Start your 7-day free trial now.
PPEMPL103
Conversion run only useful in connection with SAP DIMP
What causes this issue? You have started the report for converting PVS objects into MPL objects in an environment in which no SAP DIMP is installed. ...
PPEMPL102
Connection between MPL and PVS objects is not permitted
What causes this issue? The system has determined one of the following problems: No subrelationship can exist between the CMP nodes of a Master Parts...
PPEMPL105
Productive start of conversion report is documented
What causes this issue? When you start the report <ls>Conversion of PVS Objects to MPL Objects </> (PPE_CONVERT_PVS_MPL), it may be the c...
PPEMPL106
Cannot run report in SAP SCM
What causes this issue? The report <ls>Conversion of PVS Objects to MPL Objects</> (PPE_CONVERT_PVS_MPL) is not intended for use in an SA...
Click on this link to search all SAP messages.